Datasheet
5
162
■
EX600-SPR1A EX600-SDN1A EX600-SEN1
PROFIBUS DP (DP-V0)
DeviceNet:
Volume 1 (Edition 2.1),
Volume 3 (Edition 1.1)
EtherNet (IEEE802.3)
IP67
CE, UL (CSA)
EX600-SPR1A
EX600-SDN1A
EX600-SEN1
EX600-SEC1
EX600-SDN1A EX600-SEN1EX600-SPR1A
Subject to change
FIELDBUS
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
EX600 – serial interface unit (PROFIBUS DP,
DeviceNet, EtherNet/IP, EtherCAT)
Type
Fieldbus protocol
Communication speed
9.6; 19.2; 45.45; 93.75;
187.5 or 500 kbps; 1.5;
3; 6 or 12 Mbps
125; 250 or 500 kbps 10 or 100 Mbps
Conguration les GSD-le EDS-le EDS-le
Number of I/O 144 inputs/72 outputs
Terminating resistor Activated by built-in switch
Power consumption 80 mA or less 55 mA or less 120 mA or less
Number of valves Max. 32 depending on valve series (VQC max. 24)
Enclosure
Moisture 35–85% RH, no condensation
Operating temperature –10 to 50 °C
Standard
■ Up to 144 inputs and 72 outputs ■ Analog signals
■ Handheld terminal ■ For valve series SY, SV, S0700 and VQC
Serial interface unit
Part number Description
PROFIBUS DP node
DeviceNet node
EtherNet/IP node
EtherCAT node
5. Choose the right valve plate for mounting between
serial interface unit and the valve manifold you use.
(Example: EX600-ZMV1 for a VQC-manifold.) Valve
manifolds can be found in chapter 4.
6. Choose a DIN rail mounting if you need one, or any
enhancement parts ifmore than six EX600 modules
are included in the manifold.
7. If desired, choose a hand–held terminal for setting
and monitoring. (It is not necessary but easier for
troubleshooting and test drive.)
8. Select eldbus cabling to suit the protocol you se-
lected. See end of this chapter.
End
plate
Digital modules Analog modules
Serial inter-
face unit
Valve plate
Input
module
Input
module
Input
module
Output
module
Input/
output
module
Input
module
Input/
output
module
Power
supply
Valve manifold
The modules are
distinguished by
their colour
Four M12
connectors
Eight M12
connectors
Spring
terminal
connection
Eight M8
connectors
D-sub
connector
Two M12
connectors
Putting together an EX600–manifold is easy:
1. Determine which protocol to use and select the cor-
rect serial interface unit. (Example: EX600-SDN1A for
DeviceNet.)
2. Decide if you want digital and/or analog input mod-
ules or output modules (maximum nine). (Example: If
you want to connect eight sensors with M8 connec-
tors, choose EX600-DXPC.)
3. Select end plate with power supply. Note! if the
manifold consumption exceeds 2 A, you must select
EX600–ED3.
4. Select power supply cable connector that ts the
end plate you have chosen: M12 connection or 7/8".
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE