Datasheet

5
162
EX600-SPR1A EX600-SDN1A EX600-SEN1
PROFIBUS DP (DP-V0)
DeviceNet:
Volume 1 (Edition 2.1),
Volume 3 (Edition 1.1)
EtherNet (IEEE802.3)
IP67
CE, UL (CSA)
EX600-SPR1A
EX600-SDN1A
EX600-SEN1
EX600-SEC1
EX600-SDN1A EX600-SEN1EX600-SPR1A
Subject to change
FIELDBUS
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
EX600 serial interface unit (PROFIBUS DP,
DeviceNet, EtherNet/IP, EtherCAT)
Type
Fieldbus protocol
Communication speed
9.6; 19.2; 45.45; 93.75;
187.5 or 500 kbps; 1.5;
3; 6 or 12 Mbps
125; 250 or 500 kbps 10 or 100 Mbps
Conguration les GSD-le EDS-le EDS-le
Number of I/O 144 inputs/72 outputs
Terminating resistor Activated by built-in switch
Power consumption 80 mA or less 55 mA or less 120 mA or less
Number of valves Max. 32 depending on valve series (VQC max. 24)
Enclosure
Moisture 35–85% RH, no condensation
Operating temperature –10 to 50 °C
Standard
Up to 144 inputs and 72 outputs Analog signals
Handheld terminal For valve series SY, SV, S0700 and VQC
Serial interface unit
Part number Description
PROFIBUS DP node
DeviceNet node
EtherNet/IP node
EtherCAT node
5. Choose the right valve plate for mounting between
serial interface unit and the valve manifold you use.
(Example: EX600-ZMV1 for a VQC-manifold.) Valve
manifolds can be found in chapter 4.
6. Choose a DIN rail mounting if you need one, or any
enhancement parts ifmore than six EX600 modules
are included in the manifold.
7. If desired, choose a hand–held terminal for setting
and monitoring. (It is not necessary but easier for
troubleshooting and test drive.)
8. Select eldbus cabling to suit the protocol you se-
lected. See end of this chapter.
End
plate
Digital modules Analog modules
Serial inter-
face unit
Valve plate
Input
module
Input
module
Input
module
Output
module
Input/
output
module
Input
module
Input/
output
module
Power
supply
Valve manifold
The modules are
distinguished by
their colour
Four M12
connectors
Eight M12
connectors
Spring
terminal
connection
Eight M8
connectors
D-sub
connector
Two M12
connectors
Putting together an EX600–manifold is easy:
1. Determine which protocol to use and select the cor-
rect serial interface unit. (Example: EX600-SDN1A for
DeviceNet.)
2. Decide if you want digital and/or analog input mod-
ules or output modules (maximum nine). (Example: If
you want to connect eight sensors with M8 connec-
tors, choose EX600-DXPC.)
3. Select end plate with power supply. Note! if the
manifold consumption exceeds 2 A, you must select
EX600–ED3.
4. Select power supply cable connector that ts the
end plate you have chosen: M12 connection or 7/8".