Datasheet

4
112
02
03
02B
2
16
K
S
0
1
8
1
2
3
N NPN
EX250 EX500 EX126
DeviceNet
PROFIBUS-
DP
CC-LINK
AS-i
CANopen
DeviceNet
PROFIBUS-
DP
CC-LINK
Remote I/O
CC-LINK
+COM
N –COM
VV8 -01 N -W1-03 SDQ N 1 1
5
Rc
T NPTF
F G
1
FD0
FD1
FD2
FD3
PD0
PD1
PD2
PD3
PDC
TD0
LD0
LD1
LD2
MD0
MD1
MD2
MD3
SD0
SDA1
SDA2
SD0
SDQ
SDN
SDV
SDY
SDTA
SDTB
SDTC
SDTD
SDVB
Subject to change
SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
VSR8-4 & VSS8-4 solenoid valve, plug-in, ISO 15407-2
Port position and size
Side 1/4
Side 3/8
Bottom and side 1/4
with plug in side
Number of valve stations
2 stations
16 stations
Options
None
Special wiring
(not double
wiring)
1
Direct exhaust
with built-in silencer
If more than one option is chosen, enter
them alphabetically. Example: “KS”.
1. Ensure that wiring is entered in
manifold specification sheet.
Input block (only entered when
input blocks are used)
Without eldbus node/
input block
Without input block
With 1 input block
With 8 input blocks
Type of input block (only
entered when input blocks are used)
Without input block
M12, 2 inputs
M12, 4 inputs
M8, 4 inputs
Polarity, input block
(only entered when input blocks
are used)
PNP or without eldbus
node/input block
NPN
Fieldbus polarity
Polarity
Part number: valve manifold
Size 01
Port connection code
1. According to ISO 1179-1.
G thread.
Electrical connection/cable length
Input
D-side Connection/cable length
Valve
stations
2
F conn.
D-sub connector (25P) without cable
1 to 12
(16)
D-sub connector (25P) w. 1.5 m cable
D-sub connector (25P) w. 3 m cable
D-sub connector (25P) w. 5 m cable
P conn.
Flat cable (26P) without cable
1 to 12
(16)
Flat cable (26P) with 1.5 m cable
Flat cable (26P) with 3 m cable
Flat cable (26P) with 5 m cable
Flat cable (20P) without cable
1
1 to 9
(16)
T conn.
Terminal connection in box
1 to 10
(16)
L conn.
Cable (25 wire), 0.6 m wire length
1 to 12
(16)
Cable (25 wire), 1.5 m wire length
Cable (25 wire), 3 m wire length
M conn.
Multipole connector (26P) without cable
1 to 12
(16)
Multipole connector (26P) with 1.5 m cable
Multipole connector (26P) with 3 m cable
Multipole connector (26P) with 5 m cable
S connection
Distributed eldbus (EX500)
For eldbus without eldbus node
1 to 8
(16)
With eldbus node for Remote I/O
With eldbus node for DeviceNet/
PROFIBUS-DP/CC-LINK
Fieldbus with in- and outputs (EX250)
For eldbus without eldbus node
1 to 12
(16)
Fieldbus for DeviceNet
Fieldbus for PROFIBUS-DP
Fieldbus for CC-LINK
Fieldbus for CANopen
AS-i, 8 in/8 out, 31-slave model,
2 power supplies
1 to 4
(8)
AS-i, 4 in/4 out, 31-slave model,
2 power supplies
1 to 2
(4)
AS-i, 8 in/8 out, 31-slave model,
1 power supply
1 to 4
(8)
AS-i, 4 in/4 out, 31-slave model,
1 power supply
1 to 2
(4)
Fieldbus with outputs (EX126)
Fieldbus for CC-LINK
1 to 8
(16)
1. P connection: Order cables separately for type 20P.
2. Numbers in paranthesis indicates maximum number of solenoids for conguration
with mixed single-double solenoid connections. Maximum number of valve stations is
determined by total number of solenoids. For mixed connections, use option symbol “K”.
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE