User Manual

5.HOW TO ODER
Nil Without auto drain
N.C. (Normally closed) Drain port is closed when pressure is not applied.
Nil Without pressure gauge
Round type pressure gauge (without limit indicator)
Nil Without attachment
Mounting positionAF+T+AR+AL
Nil 0.05 to 0.7 MPa setting
0.02 to 0.2 MPa setting
Nil Polycarbonate bowl
Metal bowl
Nylon bowl
Nil Without drain cock
Lubricator with drain cock
Nil Relieving type
Non-relieving type
Nil
Flow directionLeft to right
Flow directionRight to left
Nil
Description
f
Exhaust mechanism
g
Flow direction
e
Lubricator lubricant
exhaust port
h
Pressure unit
Symbol
c
Set pressure
d
Bowl
11
a
Float type auto drain
Pressure gauge
b
Option
Semi-standard
Attachment (T-spacer)
Name plate, caution plate for bowl, and pressure gauge in imperial unitsMPa
Name plate, caution plate for bowl, and pressure gauge in imperial unitspsi, °F
1
2
3
Note 3)
Note 4)
Note 1)
Note 5)
Note 6)
Note 1) When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl.
Releasing the residual condensate before ending operations for the day is recommended.
Note 2) A 1.0 MPa pressure gauge will be fitted. It is not assembled and supplied loose at the time of shipment.
Note 3) The bracket position varies depending on the T-spacer mounting.
Note 4) Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.
Note 5) Refer to Chemical data on page 3 for chemical resistance of the bowl.
Note 6) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)
AC
10
-
M5 1N
-
A
-
1
2
1N
3
-
Option / Semi-standard : Select one each for a to h.
Option / Semi-standard symbol : When more than
one specification is required, indicate in alphanumeric order.
Example AC10-M5CG-T-12NR-A
Note 2)