Datasheet

0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure [MPa]
Outlet pressure [MPa]
Set point
0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure [MPa]
Outlet pressure [MPa]
Set point
0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure [MPa]
Outlet pressure [MPa]
Set point
Mounting/Adjustment Selection
Piping
Air Supply
Lock button
Mounting/Adjustment
1. When the bowl is installed on the air fi lter, fi lter regulator, lubri-
cator, mist separator, or micro mist separator (AC25-B to
AC60-B), install them so that the lock button lines up to the
groove of the front (or the back) of the body to avoid drop or
damage of the bowl.
Caution
Pressure Characteristics (Representative values)
Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 L/min (ANR)
Specifi c Product Precautions
1. A knob cover is available to prevent careless operation of the
knob. Refer to page 97 for details.
Caution
1. Float type auto drain
Operate under the following conditions to avoid malfunction.
<N.O. type>
· Operating compressor: 0.75 kW (100 L/min (ANR)) or more.
When using 2 or more auto drains, multiply the value above
by the number of auto drains to fi nd the capacity of the
compressors you will need.
For example, when using 2 auto drains, 1.5 kW (200 L/min
(ANR)) of the compressor capacity is required.
· Operating pressure: 0.1 MPa or more
<N.C. type>
· Operating pressure for AD27-A: 0.1 MPa or more
Operating pressure for AD37-A/AD47-A: 0.15 MPa or more
2. Use a regulator or fi lter regulator with backfl ow function when
mounting a pressure release 3 port valve on the inlet side to
ensure the release of the residual pressure. Otherwise,
residual pressure will not be fully released.
Warning
1. When releasing air at the intermediate position using a
T-spacer on the inlet side of the lubricator, lubricant may back
ow. Therefore, releasing air that does not contain traces of
lubricant is not possible.
To release air that does not contain traces of lubricant, use a
check valve (Series AKM) on the inlet side of the lubricator to
prevent a backfl ow of the lubricant.
2. If a pressure relief 3 port valve is mounted on the inlet side of
the lubricator, causing a backfl ow of air, it can result in a back-
flow of oil or damage to internal parts. Do not use it in this
fashion.
3. An F.R.L. unit shipped from the plant has its model number la-
beled. However, components that are combined together dur-
ing the distribution process do not have a label on them.
Caution
1. When mounting a check valve, make sure the arrow (IN side)
points in the correct direction of air fl ow.
Warning
1. Use an air fi lter with 5 μm or less fi ltration rating on the inlet
side of the valve to avoid any damage to the seat caused by
dust when mounting a pressure relief 3 port valve on the inlet
side.
Caution
AC50-B AC55-B AC60-B
Be sure to read this before handling. Refer to the back cover for Safety Instructions, “Handling Precautions for
SMC Products” and the Operation Manual for F.R.L. Precautions, http://www.smc.eu
12
Air Combination Series AC10-A
Air Combination Series AC20-B to AC60-B
AC
AF
AR
ALAW
ALAF
ARAF
AFM
ARAW
AFM
AF Attachment
AFM / AFD
ARALAW