User Manual

!  WARNING
Air combination
!  CAUTION
Air combination
Air filter, Filter-regulator and Mist separator
Lubricator
!  WARNING
Regulator and Filter-regulator
Operate the pressure adjusting handle manually. Tools may break the handle.
Lubricator
!  CAUTION
Regulator and Filter-regulator
Check inlet pressure before setting up.
Pull the pressure regulator handle to unlock. (You can visually verity this with the "orange
mark" that appears in the gap.)
Installation
Adjustment
Adjust the pressure adjusting handle ensuring correct inlet pressure and outlet pressure.
Excessive rotation may cause damage to internal parts.
Adjustment of the oil adjustment valve should be carried out manually. The use of tools, etc. can
result in damage to the unit. (AL20-A to AL60-A)
Install the bowl vertically with bowl facing down. If it is inclined, dripping may not be confirmed.
Turning the oil adjustment valve counterclockwise increases the dripping amount, and turning it
clockwise reduces the dripping amount. From the fully closed position, three rotations will bring it
to the fully open position. Please do not rotate it any further than this.
Note that the numbered scale markings are guidelines for adjusting the position, and not
indicators of the dripping amount. (AL20-A to AL60-A)
Connect the product ensuring the direction of " " (IN) and " " (OUT) for air direction or an
arrow. Wrong connection may cause malfunction.
Install with enough space around each assembly component to perform regular maintenance and
operation. The required space is shown on 11. Dimensions (P20 to 24).
Do not drop or apply impact during transportation or installation. It will cause damage to the
product or operation failure.
Do not install in areas of high humidity or high temperature. The product cannot be used in the
horizontal or upward directions outside of the specifications.
Install vertically so that outlet of drain would turned downward. Use with the outlet of drain turned
horizontal or upward causes malfunction.
djust pressure incrementally. Pressure may become lower than set pressure if adjusted by
decreasing the value. Rotate the handle clockwise to raise the set pressure. Counterclockwise to
reduce the pressure. Moreover, please lock the handle after setting pressure.
Outlet pressure may rise if eliminate the inlet pressure after pressure setting and supply pressure
again. The pressure becomes close to the set pressure after air is consumed in outlet.
Be sure to unlock the handle before adjusting the pressure and lock it after setting the pressure.
Failure to follow this procedure can damage the handle and the outlet pressure may fluctuate.
5
Outlet pressure may change if filter regulator is used for long periods. Please confirm set
pressure regularly.
For the regulator with the pressure gauge, do not apply pressure exceeding the maximum scale
of the pressure gauge in order to protect the gauge.
Push the pressure regulator handle to lock. When the handle is not easily locked, turn it
left and right a little and then push it. (When the handle is locked, the "orange mark", i.e.,
the gap will disappear.)
On AL10-A, some dripping may occur even when needle is fully opened.