User Manual

20 30 40 50 60
Nil
01
02
03
04
06
10
Nil
Without auto drain
N.C. (Normally closed) Drain port is closed when pressure is not applied.
N.O. (Normally open) Drain port is open when pressure is not applied.
Nil
Without pressure gauge
Round type pressure gauge (with limit indicator)
Round type pressure gauge (with color zone)
E1
OutputNPN output / Electrical entryWiring bottom entry
E2
OutputNPN output / Electrical entryWiring top entry
E3
OutputPNP output / Electrical entryWiring bottom entry
E4
OutputPNP output / Electrical entryWiring top entry
Nil
Without attachment
Mounting positionAW+K+AL
Nil
Without attachment
Mounting positionAW+S+AL
Nil
Without attachment
Mounting positionAW+AL+V
Nil
0.05 to 0.85 MPa setting
0.02 to 0.2 MPa setting
Nil
Polycarbonate bowl
Metal bowl
Nylon bowl
Metal bowl with level gauge
With bowl guard
6C
With bowl guard (Nylon bowl)
Nil With drain cock
Drain guide 1/8
Drain guide 1/4
Drain cock with barb fitting (for φ 6 x φ 4 nylon tube)
Nil
Without drain cock
Lubricator with drain cock
Nil
Relieving type
Non-relieving type
Nil
Flow directionLeft to right
Flow directionRight to left
Nil
ZA Digital pressure switchWith unit conversion function
Symbol
Description
Body size
Pipe thread type
Rc
NPT
Port size
1/8
1/4
3/8
1/2
3/4
Flow direction
Option
a
Float type
auto drain
b
Pressure gauge
Digital
pressure
switch
Attachment
c
Check valve
d
Pressure switch
e
Pressure relief
3 port valve
Semi-standard
f
Set pressure
g
Bowl
h
Filter regulator
drain port
l
Pressure unit
Square embedded type pressure gauge (with limit indicator)
Name plate, caution plate for bowl, and pressure gauge in imperial unitsMPa
Name plate, caution plate for bowl, and pressure gauge in imperial unitspsi, °F
14
i
Lubricator
lubricant
exhaust port
j
Exhaust
mechanism
k
1
2
3
4
6
5
Note 7)
AC
30
-
03
DE
1N
-
B
-
1
3
4
5
2
1N
6
-
A
Option / Semi-standard : Select one each for a to l.
Option / Attachment / Semi-standard symbol : When more than
one specification is required, indicate in alphanumeric order.
Example AC30A-F03DE1-KSV-136NR-B
Note 3)
Note 1)
Note 2)
Note 4)
Note 5)
Note 6)
Note 8)
Note 9)
Note 10)
Note 13)
Note 14)
Note 15)
Note11)
Note12)
Note11)
Note12)
Note11)
Note12)
Note11)
Note12)
Note 16)
Note 17)
Note 18)
Note19)
Note20)
Note19)
Note20)
Note19)
Note20)
Note19)
Note20)
Note19)
Note20)
Note 1) Drain guide is NPT1/8 (applicable to the AC20A-B) and
NPT1/4 (applicable to the AC30A-B to AC60A-B).
The auto drain port comes with φ3/8" One-touch fitting
(applicable to the AC30A-B to AC60A-B).
Note 2) Drain guide is G1/8 (applicable to the AC20A-B) and
G1/4 (applicable to the AC30A-B to AC60A-B).
Note 3) Option G, M are not assembled and supplied loose
at the time of shipment.
Note 4) When pressure is not applied, condensate which
does not start the auto drain mechanism will be left in
the bowl. Releasing the residual condensate before
ending operations for the day is recommended.
Note 5) If the compressor is small (0.75 kW, discharge flow is less
than 100 L/min[ANR]), air leakage from the drain cock
may occur during start of operations. N.C. type is
recommended.
Note 6) When the pressure gauge is attached, a 1.0 MPa pressure gauge
will be fitted for standard (0.85 MPa) type.
0.4 MPa pressure gauge for 0.2 MPa type.
Note 7) Not available with piping port size: 06
Note 8) The bracket position varies depending on the pressure switch
mounting.
Note 9) Pressure can be set higher than the specification pressure
in some cases, but use pressure within the specification range.
Note 10) Refer to Chemical data on page 3 for chemical resistance
of the bowl.
Note 11) A bowl guard is provided as standard equipment (polycarbonate).
Note 12) A bowl guard is provided as standard equipment (nylon).
Note 13) Float type auto drain: The combination of C and D is
not possible.
Note 14) Without a valve function.
Note 15) The combination of metal bowl: 2 and 8 is not available.
Note 16) When choosing with W: Filter drain port, the drain cock of a
lubricator will be with barb fittings.
Note 17) For pipe thread type: NPT.
This product is for overseas use only according to the new
Measurement Law. (The SI unit type is provided for use in Japan.)
Cannot be used with M: Round pressure gauge (with color zone).
Available by request for special.
The digital pressure switch will be equipped with the unit
conversion function, setting to psi initially.
Note 18) For options: E1, E2, E3, E4. This product is for overseas use only
according to the new Measurement Law. (The SI unit is provided
for use in Japan.)
Note 19) : For pipe thread type: NPT only
Note 20) : Select with options: E1, E2, E3, E4.