Gigabit Ethernet Switch Management Guide

C
ONSOLE
I
NTERFACE
2-16
Configuring the Serial Port
You can access the on-board configuration program by attaching a
VT100 compatible device to the switchs serial port. (For more
information on connecting to this port, see Required
Connections on page 1-2.) The communication parameters for
this port can be accessed from the Serial Port Configuration screen
shown below and described in the following table.
SMC TigerSwitch 1000 Local Management -- SMC8606T
< Serial Port Configuration >
Management Mode : CONSOLE MODE
Baud rate : 19200
Data bits : 8
Stop bits : 1
Parity : NONE
Time-Out (in minutes) : 10
<APPLY> <OK> <CANCEL>
Use <TAB> or arrow keys to move, <Space> to scroll options.
Parameter Default Description
Management
Mode
Console
Mode
Indicates that the console port
settings are for direct console
connection.
Baud Rate 19200 The rate at which data is sent between
devices.
Options : 2400, 4800, 9600, 19200 bps,
and Auto detection
Data bits 8 bits Sets the data bits of the RS-232 port.
Options : 7, 8