Gigabit Ethernet Switch Management Guide

C
ONSOLE
I
NTERFACE
2-11
Changing the Network Configuration
Use the Network Configuration menu to set the bootup option,
configure the switchs Internet Protocol (IP) parameters, enable the
on-board Web server, or to set the number of concurrent Telnet
sessions allowed. The screen shown below is described in the
following table.
SMC TigerSwitch 1000 Local Management -- SMC8606T
< Network Configuration >
IP Configuration
IP Connectivity Test(Ping)
HTTP Configuration
MAX Number of allowed Telnet sessions (1-4) : 4
Physical Address : 00-00-11-11-43-21
<APPLY> <OK> <CANCEL>
Use <TAB> or arrow keys to move. <Enter> to select.
Parameter Description
IP Configuration Screen used to set the bootup option, or configure
the switchs IP parameters.
IP Connectivity
Test
Screen used to test IP connectivity to a (Ping)
specified device.
HTTP
Configuration
Screen used to enable the Web server.
MAX Number of
Allowed Telnet
Sessions
The maximum number of Telnet sessions allowed
to simultaneously access the switch.
Physical Address MAC address of the switch.