EZ Switch 10/100/1000 User Guide From SMC’s EZ line of low-cost workgroup LAN solutions 38 Tesla Irvine, CA 92618 Phone: (949) 679-8000 December 2003 Pub.
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice. SMC Networks, Inc. 38 Tesla Irvine, CA 92618. All rights reserved.
LIMITED WARRANTY Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term.
LIMITED WARRANTY WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
COMPLIANCES FCC - Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications.
COMPLIANCES • Radio-frequency electromagnetic field according to EN 61000-4-3:1996 (80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m) • Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV) • Surge immunity test according to EN 61000-4-5:1995 (AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV) • Immunity to conducted disturbances, Induced by radio-frequency fields: EN 61000-4-6:1996 (0.
COMPLIANCES Safety Compliance Underwriters Laboratories Compliance Statement Important! Before making connections, make sure you have the correct cord set.
COMPLIANCES Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung. 4. Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein. 5. Das Gerät ist vor Feuchtigkeit zu schützen. 6.
TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Front Panel RJ-45 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SMC8516T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TABLE OF CONTENTS viii
INTRODUCTION The EZ Switch™ 10/100/1000, SMC8516T, is a high-performance Gigabit Ethernet switch designed for delivering Gigabit connectivity to the desktop. It provides 16 full-duplex 1000BASE-T ports that significantly improve network performance and boost throughput for high-bandwidth applications. With 32 Gigabits of aggregate bandwidth, this switch provides the quickest solution to meeting the growing demands on your network’s limited resources.
INTRODUCTION Front Panel RJ-45 Ports The EZ Switch 10/100/1000 features 16 1000BASE-T ports with RJ-45 connectors located on the front panel of the switch. Because all ports support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs. Front Panel LEDs The front panel of the switch provides status LEDs for “at-a-glance” system monitoring. The following table details the functions of the various indicators.
REAR PANEL SMC8516T EZ Switch 10/100/1000 8516T Power 3 4 5 1 2 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Link/Act 1000/100M Link/Act 1000/100M 100-240V ~ 50-60Hz 2A Rear Panel The AC power receptacle is located on the rear panel of the switch.
INSTALLING THE SWITCH Before installing the switch, verify that you have all the items listed under “Package Contents.” Note that the switch can be installed on any suitably large flat surface or in a standard EIA 19-inch rack.
INSTRUCTIONS • There should be adequate space (approximately two inches) on all sides for proper air flow. • Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference such as radios, transmitters, etc. • Make sure that a properly grounded power outlet is within 2.44 meters (8 feet) of the switch and is powered from an independent circuit breaker.
INSTALLING THE SWITCH 4. Cascading Switches and Other Network Devices: All the ports on the switch support automatic MDI/MDI-X configuration for cable connections. This allows you to use straight-through cable to connect to other switches or hubs from any port on the switch. No crossover cables or other device settings are needed. See the “Cable Specifications” on page 9 of this guide for further information. Caution: 6 Do not plug a phone jack connector into any RJ-45 port. This may damage the switch.
APPLICATION EXAMPLE A typical application for the SMC8516T is illustrated below.
TROUBLESHOOTING Diagnosing Switch Indicators 1. Symptom Power LED does not light after power on. Probable Causes • AC power cord may be defective. Possible Solutions • Check for loose connections. • Check the power outlet by using it for another device. • Replace the AC power cord. 2. Symptom Link LED does not light after connection is made. Probable Causes • Switch port, network card or cable may be defective. Possible Solutions • Check that the switch and attached device are both powered on.
CABLES Cable Specifications Cable 10BASE-T 100BASE-TX 1000BASE-T Cable Types and Specifications Type Max. Length 2-pair Cat. 3 or better 100-ohm UTP 100 m (328 ft) 2-pair Cat. 5 or better 100-ohm UTP 100 m (328 ft) 4-pair Cat. 5 or better 100-ohm UTP 100 m (328 ft) Connector RJ-45 RJ-45 RJ-45 10BASE-T/100BASE-TX Pin Assignments Caution: DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards.
CABLES The table below shows the 10BASE-T/100BASE-TX MDI-X and MDI port pinouts. Pin MDI-X Signal Name MDI Signal Name 1 Receive Data plus (RD+) Transmit Data plus (TD+) 2 Receive Data minus (RD-) Transmit Data minus (TD-) 3 Transmit Data plus (TD+) Receive Data plus (RD+) 6 Transmit Data minus (TD-) Receive Data minus (RD-) 4,5,7,8 Not used at 10/100 Mbps Not used at 10/100 Mbps 1000BASE-T Pin Assignments The table below shows the 1000BASE-T MDI and MDI-X port pinouts.
1000BASE-T CABLE REQUIREMENTS 1000BASE-T Cable Requirements All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, 4-pair Category 5e (enhanced Category 5) cable should be used. The Category 5e specifications include test parameters that are only recommendations for Category 5.
PRODUCT SPECIFICATIONS EZ Switch 10/100/1000 Standards Conformance IEEE 802.3 IEEE 802.3u IEEE 802.3x IEEE 802.3ab Communication Rate 10, 100, and 1000 Mbps Communication Mode Full or half duplex at 10/100 Mbps Full duplex at 1000 Mbps Media Supported 10BASE-T: 100-ohm Category 3 or better twisted-pair 100BASE-TX: 100-ohm 2-pair Category 5 or better twisted pair 1000BASE-T: 100-ohm 4-pair Category 5/5e twisted-pair Indicator Panel Power Ports: Link/Act, 100/1000M Dimensions 33 x 23 x 4.4 cm (12.99 x 9.
PRODUCT SPECIFICATIONS Weight 2.494 kg (5.05 lbs) MAC Address Table 8 K entries Memory Buffer 400 Kbits on-chip frame buffer Power Consumption 38 Watts Heat Dissipation 130 BTU/hr maximum Power Requirement Input Voltage: 100 - 240 VAC@50/60 Hz Temperature Operating: 0 ~ 40 ºC / 32 ~ 98 ºF Storage: -40 ~ 70 ºC / -40 ~ 158 ºF Humidity 10% to 90% non-condensing EMC/Safety Compliances CE Mark Immunity EN 61000-4-2/3/4/5/6/8/11 Emissions FCC Class A, CISPR Class A, EN 61000-3-2/3 Safety CSA/NRTL (C22.2.
PRODUCT SPECIFICATIONS 14
FOR TECHNICAL SUPPORT, CALL: From U.S.A. and Canada (24 hours a day, 7 days a week) (800) SMC-4-YOU; Phn: (949) 679-8000; Fax: (949) 679-1481 From Europe : Contact details can be found on www.smc-europe.com or www.smc.com INTERNET E-mail addresses: techsupport@smc.com european.techsupport@smc-europe.com Driver updates: http://www.smc.com/index.cfm?action=tech_support_drivers_downloads World Wide Web: http://www.smc.com http://www.smc-europe.com FOR LITERATURE OR ADVERTISING RESPONSE, CALL: U.S.A.