24-Port Layer 3 Switch Management Guide

S
YSTEM
M
ANAGEMENT
C
OMMANDS
4-41
Example
The following example shows that system logging is enabled, the message
level for flash memory is “errors” (i.e., default level 3 - 0), the message
level for RAM is “debugging” (i.e., default level 7 - 0), and lists one sample
error
Time Commands
The system clock can be dynamically set by polling a set of specified time
servers (NTP or SNTP), or by using information broadcast by local time
servers.
Console#show logging flash
Syslog logging: Enable
History logging in FLASH: level errors
[0] 0:0:5 1/1/1
"PRI_MGR_InitDefault function fails."
level: 3, module: 13, function: 0, and event no.: 0
Console#show logging ram
Syslog logging: Enable
History logging in RAM: level debugging
[0] 0:0:5 1/1/1
"PRI_MGR_InitDefault function fails."
level: 3, module: 13, function: 0, and event no.: 0
Console#
Command Function Mode Page
sntp client Accepts time from specified time servers GC 4-42
sntp server Specifies one or more time servers GC 4-43
sntp poll Sets the interval at which the client polls for time GC 4-44
sntp broadcast
client
Accepts time from any time broadcast server GC 4-45
show sntp Shows current SNTP configuration settings NE,
PE
4-45
clock timezone Sets the time zone for the switch’s internal clock GC 4-46