TigerSwitch 10/100 24-Port Fast Ethernet Switch ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 24 10BASE-T/100BASE-TX ports Optional 1000BASE-X or 100BASE-FX modules 8.
TigerSwitch 10/100 Installation Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions 38 Tesla Irvine, CA 92618 Phone: (949) 679-8000 October 2003 Pub.
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice. SMC Networks, Inc. 38 Tesla Irvine, CA 92618. All rights reserved.
LIMITED WARRANTY Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term.
WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
COMPLIANCES FCC - Class A This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
COMPLIANCES EC Conformance Declaration - Class A SMC contact for these products in Europe is: SMC Networks Europe, Edificio Conata II, Calle Fructuós Gelabert 6-8, 2o, 4a, 08970 - Sant Joan Despí, Barcelona, Spain.
COMPLIANCES Japan VCCI Class A Taiwan BSMI Class A Australia AS/NZS 3548 (1995) - Class A SMC contact for products in Australia is: SMC Communications Pty. Ltd.
COMPLIANCES Safety Compliance Warning: Fiber Optic Port Safety CLASS I LASER DEVICE When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on. Avertissment: Ports pour fibres optiques - sécurité sur le plan optique DISPOSITIF LASER DE CLASSE I Ne regardez jamais le laser tant qu’il est sous tension.
COMPLIANCES Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung. 4. Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein. 5. Das Gerät ist vor Feuchtigkeit zu schützen. 6.
COMPLIANCES viii
TABLE OF CONTENTS 1 About the TigerSwitch 10/100 . . . . . . . . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Switch Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Management Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Description of Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 RJ-45 Ports .
TABLE OF CONTENTS Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Desktop or Shelf Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing an Optional Module into the Switch . . . . . . . . . . . . . . Connecting to a Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting to the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Map for Serial Cable . . . . . . . . . . . . . . .
TABLE OF CONTENTS APPENDICES: A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnosing Switch Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Power and Cooling Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 In-Band Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TABLE OF CONTENTS D Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 1 ABOUT THE TIGERSWITCH 10/100 Overview SMC’s TigerSwitch™ 10/100 (SMC6724AL2) contains 24 10BASE-T / 100BASE-TX (RJ-45) ports plus two slots on the front panel for slide-in modules (100BASE-FX or 1000BASE-X/T). There is also an SNMP-based management agent embedded on the main board. This agent supports both in-band and out-of-band access for managing the switch.
ABOUT THE TIGERSWITCH 10/100 Switch Architecture The switch employs a wire-speed, non-blocking switching fabric. This permits simultaneous wire-speed transport of multiple packets at low latency on all ports. This switch also features full-duplex capability on all ports, which effectively doubles the bandwidth of each connection. Auto-negotiation is used to select the optimal transmission speed and communication mode for each connection.
DESCRIPTION OF HARDWARE Description of Hardware RJ-45 Ports The switch base unit contains 24 10BASE-T / 100BASE-TX RJ-45 ports. All of these ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
ABOUT THE TIGERSWITCH 10/100 Status LEDs The LEDs, which are located on the front panel for easy viewing, are shown below and described in the following table. Link/Activity 1 2 3 4 5 6 7 8 9 10 11 12 Figure 1-2. Port LEDs Table 1-1. Port Status LEDs Port Status LEDs LED Condition Status Base Unit Ports 1~24 (Link/Act) On/ Flashing Amber Port has established a valid 10 Mbps network connection. Flashing indicates activity.
DESCRIPTION OF HARDWARE Power Indicator PWR Diag M1 M2 Diagnostic Test Indicator Figure 1-3. System LEDs Table 1-2. System Status LEDs System Status LEDs LED Condition Status PWR On Green The unit’s internal power supply is operating normally. Off The unit has no power connected. On Green The system diagnostic test has completed successfully. Flashing Green The system diagnostic test is in progress. On Amber The system diagnostic test has detected a fault.
ABOUT THE TIGERSWITCH 10/100 Optional Media Extender Modules Optional 10/100/1000BASE-T Module (SMC6824GT) 10/100/1000BASE-T Gigabit Module SMC6824GT Figure 1-4. Single-Port 1000BASE-T Gigabit Module Using Category 5, 5e, or 6 twisted-pair cable you can connect to another device up to 100 m (328 ft) away. The 1000BASE-T module operates at 10/100/1000 Mbps. At 1000 Mbps it operates at full duplex and supports auto-negotiation of speed and flow control.
DESCRIPTION OF HARDWARE Optional 100BASE-FX Module (SMC6824FMSC) 100BASE-FX Multimode Module TX RX SMC6824FMSC Figure 1-6. Single-Port 100BASE-FX Multimode Module Using multimode fiber optic cable, the 100BASE-FX port can be connected to a remote site up to 2 km (1.24 miles) away. The 100BASE-FX module is fixed to operate at 100 Mbps full duplex, and supports auto-negotiation for flow control.
ABOUT THE TIGERSWITCH 10/100 connection. This port can be connected to a site up to 5 km (16404 ft) away with single-mode fiber cable. 1000BASE-ZX GBIC transceivers provide one long-wavelength (1550 nm) Gigabit port that can be used for a long-haul connection to a remote location. This port can be connected to a site up to 100 km (62.1 miles) away with single-mode fiber cable. Caution: Install only 5 V GBIC transceivers into the module slots.
FEATURES AND BENEFITS Features and Benefits Connectivity ◆ 24 dual-speed ports for 10 or 100 Mbps Ethernet connections ◆ Auto-negotiation enables each RJ-45 port to automatically select the optimum communication mode (half or full duplex) if this feature is supported by the attached device; otherwise the port can be configured manually ◆ Independent RJ-45 ports with support for automatic MDI/MDI-X ◆ Unshielded (UTP) cable supported on all RJ-45 ports: Category 3 or better for 10 Mbps connections and
ABOUT THE TIGERSWITCH 10/100 ◆ Filtering and forwarding at line speed ◆ Desktop or rack-mountable Management 1-10 ◆ “At-a-glance” LEDs for easy troubleshooting ◆ Management agent: • Supports Telnet, SNMP and Web-based interface • Manages switch in-band or out-of-band
CHAPTER 2 NETWORK PLANNING Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today's networking technology.
NETWORK PLANNING Application Examples The TigerSwitch 10/100 is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described below. Collapsed Backbone The TigerSwitch 10/100 is an excellent choice for mixed Ethernet and Fast Ethernet installations where significant growth is expected in the near future.
APPLICATION EXAMPLES Network Aggregation Plan With 26 parallel bridging ports (i.e., 26 distinct collision domains), this switch can collapse a complex network down into a single efficient bridged node, increasing overall bandwidth and throughput. In the figure below, the 10BASE-T/100BASE-TX ports on the switch are providing 100 Mbps connectivity for up to 24 segments. In addition, the switch is also connecting servers at 100 Mbps.
NETWORK PLANNING Remote Connection with Fiber Cable Fiber optic technology allows for longer cabling than any other media type. A 100 Mbps multimode fiber (MMF) link can run up to 2 km, and a 100 Mbps single-mode fiber (SMF) link can run as far as 20 km. This allows the switch to serve as a collapsed backbone, providing direct connectivity for a widespread LAN. The 100BASE-FX (SMF) plug-in module or 1000BASE-ZX GBIC transceiver can be used to interconnect remote network segments.
APPLICATION EXAMPLES Making VLAN Connections VLANs can be based on port groups, or each data frame can be explicitly tagged to identify the VLAN group to which it belongs. When using port-based VLANs, ports can either be assigned to one specific group or to all groups. Port-based VLANs are suitable for small networks. A single switch can be easily configured to support several VLAN groups for various organizational entities (such as Finance and Marketing).
NETWORK PLANNING Application Notes 1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. 2. Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem. Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub. 3.
CHAPTER 3 INSTALLING THE SWITCH Selecting a Site TigerSwitch 10/100 units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. ◆ The site should: • be at the center of all the devices you want to link and near a power outlet.
INSTALLING THE SWITCH Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T or 100BASE-TX operation. Check the following criteria against the current installation of your network: • Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ-45 connectors; Category 3 or better for 10BASE-T and Category 5 or better for 100BASE-TX.
EQUIPMENT CHECKLIST Equipment Checklist After unpacking the TigerSwitch 10/100, check the contents to be sure you have received all the components. Then, before beginning the installation, be sure you have all other necessary installation equipment.
INSTALLING THE SWITCH Mounting A TigerSwitch 10/100 unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Installing Optional Modules: Before mounting the switch, be sure you install any optional modules. If you have purchased optional slide-in 1000BASE-T, 100BASE-FX or GBIC media expansion module, install these modules now, following the instructions in “Installing an Optional Module into the Switch” on page 3-7.
MOUNTING To rack-mount devices: 1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit. PW R Di ag M1 M2 Figure 3-2. Attaching the Brackets 2. Mount the device in the rack, using four rack-mounting screws (not provided). PW R Di ag M1 M2 Figure 3-3. Installing the Switch in a Rack 3. If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter. 4.
INSTALLING THE SWITCH Desktop or Shelf Mounting 1. Attach the four adhesive feet to the bottom of the first switch. M2 M1 PW R Dia g 19 20 21 22 23 24 Figure 3-4. Attaching the Adhesive Feet 2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow. 3. If installing a single switch only, go to “Connecting to a Power Source” at the end of this chapter. 4.
MOUNTING Installing an Optional Module into the Switch PW R Di ag M1 M2 100BA SE-FX Single mode Modul e TX RX Figure 3-5. Installing an Optional Module Caution: DO NOT install slide-in modules with the switch powered on. Be sure you power off the switch before installing any module. To install an optional module into the switch, do the following: 1. Disconnect power to the switch. 2.
INSTALLING THE SWITCH Connecting to a Power Source To connect a device to a power source: 1. Insert the power cable plug directly into the receptacle located at the back of the device. 100-240V~ 50-60Hz 2A Figure 3-6. Power Receptacle 2. Plug the other end of the cable into a grounded, 3-pin socket. Note: For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the receptacle type in your country. 3.
CONNECTING TO THE CONSOLE PORT Connecting to the Console Port The DB-9 serial port on the switch’s front panel is used to connect to the switch for out-of-band console configuration. The on-board menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation program. The pin assignments used to connect to the serial port are provided in the following tables. 1 6 5 9 Figure 3-7. Serial Port (DB-9 DTE) Pin-Out Wiring Map for Serial Cable Table 3-1.
INSTALLING THE SWITCH 3-10
CHAPTER 4 MAKING NETWORK CONNECTIONS Connecting Network Devices The TigerSwitch 10/100 may be connected to 10 or 100 Mbps network cards in PCs and servers, as well as to other switches and hubs. It may also be connected to remote devices using the optional fiber optic modules. Twisted-Pair Devices Each device requires a shielded or unshielded twisted-pair (STP or UTP) cable with RJ-45 connectors at both ends.
MAKING NETWORK CONNECTIONS have an MDI port, so that they can connect to another switch’s/hub’s MDI-X port using straight-through cable. To connect between two switches/hubs that only have fixed MDI-X ports, the wiring crossover must be implemented in the cable - known as a crossover cable. The RJ-45 ports on the switch base unit support automatic MDI/MDI-X operation, which means that they automatically detect the wiring in the link and configure as MDI or MDI-X accordingly.
TWISTED-PAIR DEVICES is connected to the wiring closet (see “Wiring Closet Connections” on page 4-3 on the next page). Otherwise, attach the other end to an available port on the switch. 3. Make sure each twisted pair cable does not exceed 100 meters (328 ft) in length. Note: When connected to a shared collision domain (such as a hub with multiple workstations), switch ports must be set to half-duplex mode and back pressure flow control disabled. 4.
MAKING NETWORK CONNECTIONS 3. Label the cables to simplify future troubleshooting. SMC TigerSwitch 10/100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Equipment Rack (side view) 23 24 PWR Diag M1 M2 Punch-Down Block Patch Panel Wall Figure 4-2. Wiring Closet Connections Fiber Optic Devices An optional slide-in 100BASE-FX module can be used for backbone and long distance connections. Each multimode fiber optic port requires 50/125 or 62.
FIBER OPTIC DEVICES Warning: This switch uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on. 1. Remove and keep the SC port’s rubber cover. When not connected to a fiber cable, the rubber cover should be replaced to protect the optics. 2. Check that the fiber terminators are clean.
MAKING NETWORK CONNECTIONS 4. As a connection is made, check the Activity LED on the switch’s front panel for the corresponding module to be sure that the connection is valid. Note: If you use the optional SC-ST Converter, be sure to connect the converter’s Tx (Rx) port to the Rx (Tx) port on the other device. The 100BASE-FX fiber optic ports operate only at 100 Mbps, full duplex. You can run a single-mode fiber link up to 20 kilometers (12.43 miles).
CONNECTIVITY RULES 1000BASE-T is a simple test of the cable installation to be sure that it complies with the IEEE 802.3ab standards. 1000 Mbps Gigabit Ethernet Collision Domain Maximum Cable Distance for 1000BASE-T Type Connector Maximum Cable Length Cat. 5, 5e, or 6 100-ohm UTP RJ-45 100 m (328 ft) 10/100 Mbps Ethernet Collision Domain Maximum 10/100 Mbps Ethernet Cable Distance Type Cable Type Max.
MAKING NETWORK CONNECTIONS Cable Labeling and Connection Records When planning a network installation, it is essential to label the opposing ends of cables and to record where each cable is connected. Doing so will enable you to easily locate inter-connected devices, isolate faults and change your topology without need for unnecessary time consumption. To best manage the physical implementations of your network, follow these guidelines: 4-8 • Clearly label the opposing ends of each cable.
APPENDIX A TROUBLESHOOTING Diagnosing Switch Indicators Troubleshooting Chart Symptom Action Power LED is Off • Internal power supply has failed or is disconnected. • Check connections between the switch, the power cord, the wall outlet. • Contact SMC Technical Support. • Verify that the switch and attached device are powered on. Be sure the cable is plugged into both the switch and corresponding device. Verify that the proper cable type is used and its length does not exceed specified limits.
TROUBLESHOOTING Power and Cooling Problems If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the unit are unobstructed and running prior to shutdown.
APPENDIX B CABLES Specifications Cable Types and Specifications Cable Type Max. Length Connector 10BASE-T Cat. 3 or better 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-TX Cat. 5 or better 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-FX 50/125 or 62.5/125 micron 2 km (1.24 miles) core multimode fiber (MMF) 100BASE-FX 9/125 micron core single-mode fiber (SMF) 1000BASE-T SC or ST 20 km (12.43 miles) SC Cat. 5, 5e, or 6 100-ohm UTP 100 m (328 ft) RJ-45 1000BASE-SX 50/125 or 62.
CABLES Twisted-Pair Cable and Pin Assignments Caution: DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards. For 100BASE-TX/10BASE-T connections, a twisted-pair cable must have two pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be green and the other, white with green stripes. Also, an RJ-45 connector must be attached to both ends of the cable.
TWISTED-PAIR CABLE AND PIN ASSIGNMENTS The RJ-45 ports on the switch base unit support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of the cable. When using any RJ-45 port on this switch, you can use either straight-through or crossover cable..
CABLES Crossover Wiring If the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be implemented in the wiring. (When auto-negotiation is enabled for any RJ-45 port on this switch, you can use either straight-through or crossover cable to connect to any device type.
TWISTED-PAIR CABLE AND PIN ASSIGNMENTS 1000BASE-T MDI and MDI-X Port Pinouts Pin MDI Signal Name MDI-X Signal Name 1 Bi-directional Data One Plus (BI_D1+) Bi-directional Data Two Plus (BI_D2+) 2 Bi-directional Data One Minus (BI_D1-) Bi-directional Data Two Minus (BI_D2-) 3 Bi-directional Data Two Plus (BI_D2+) Bi-directional Data One Plus (BI_D1+) 4 Bi-directional Data Three Plus (BI_D3+) Bi-directional Data Four Plus (BI_D4+) 5 Bi-directional Data Three Minus (BI_D3-) Bi-directional Data
CABLES Adjusting Existing Category 5 Cabling If your existing Category 5 installation does not meet one of the test parameters for 1000BASE-T, there are basically three measures that can be applied to try to correct the problem: 1. Replace any Category 5 patch cables with high-performance Category 5e or 6 cables. 2. Reduce the number of connectors used in the link. 3. Reconnect some of the connectors in the link.
CONSOLE PORT PIN ASSIGNMENTS Console Port Pin Assignments The DB-9 serial port on the switch’s front panel is used to connect to the switch for out-of-band console configuration. The on-board menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation program. The pin assignments used to connect to the serial port are provided in the following tables. Pin 1 Pin 9 Figure B-4.
CABLES Console Port to 25-Pin DTE Port on PC Switch’s 9-Pin Serial Port 2 RXD 3 TXD 5 SGND Null Modem <---------TXD ----------------------RXD ----------> -----------SGND ---------- No other pins are used.
APPENDIX C SPECIFICATIONS Physical Characteristics Base Unit Ports 24 10BASE-T/100BASE-TX, with auto-negotiation Media Slot 2 slots for optional 100BASE-FX, 1000BASE-T, or 1000BASE-X (GBIC) modules Network Interface 10BASE-T: RJ-45 (100-ohm, UTP cable; Categories 3 or better) 100BASE-TX: RJ-45 (100-ohm, UTP cable; Category 5 or better) Ports 1-24: RJ-45 connectors, auto MDI/MDI-X Communication Speed 10 and 100 Mbps Communication Mode Full and half duplex Buffer Architecture 4 Mbyte per system Aggregate Band
SPECIFICATIONS LEDs System: PWR (Power), Diag (Diagnostics) Ports: Link/Activity Weight 3.08 kg (6 lb. 13 oz.) Size 44 x 32.4 x 4.3 cm (17.32 x 12.8 x 1.69 in.) Temperature Operating: 0 to 50 °C (32 to 122 °F) Storage: -40 to 70 °C (-40 to 158 °F) Humidity Operating: 10% to 90% Power Supply Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 Hz Power Consumption 60 Watts maximum Heat Dissipation 205 BTU/hr maximum Maximum Current 3.0 A @ 110 VAC 2.
MANAGEMENT FEATURES Flow Control Full Duplex: IEEE 802.3x Half Duplex: Back pressure Management Features In-Band Management Telnet, Web-based HTTP, or SNMP manager (EliteView Network Management software provided free) Out-of-Band Management RS-232 DB-9 console port Software Loading TFTP or Web (HTTP) in-band, or XModem out-of-band MIB Support MIB II (RFC1213), Bridge MIB (RFC 1493, without Static Table), SMC’s private MIB Standards IEEE 802.3 Ethernet, IEEE 802.3u Fast Ethernet IEEE 802.
SPECIFICATIONS Compliances CE Mark Emissions FCC Class A Industry Canada Class A EN55022 (CISPR 22) Class A EN 61000-3-2/3 VCCI Class A C-Tick - AS/NZS 3548 (1995) Class A Immunity EN 61000-4-2/3/4/5/6/8/11 Safety CSA/NRTL (CSA 22.2.
SLIDE-IN MODULES Slide-in Modules 100BASE-FX Extender Modules Models SMC6824FSSC, SMC6824FMSC Ports 1 100BASE-FX Network Interface SMC6824FSSC: 9/125 micron single-mode fiber cable SMC6824FMSC 50/125 or 62.5/125 micron multimode fiber cable Standards IEEE 802.3u Fast Ethernet ISO/IEC 8802-3 Weight 50 gm (1.8 oz) Size 6.0 x 9.1 cm ( 2.37 x 2.56 in.
SPECIFICATIONS Weight 55 gm (1.98 oz) Size 6.0 x 9.1 cm ( 2.37 x 2.56 in.) 1000BASE-X GBIC Module Model SMC6824GB Ports 1 slot for GBIC transceivers Communication Speed 1000 Mbps Communication Mode Full Duplex Standards IEEE 802.
APPENDIX D ORDERING INFORMATION TigerSwitch 10/100 Products and Accessories Product Number Description SMC6724AL2 24-port Fast Ethernet switch with two media expansion slots SMC6824GT Gigabit module with one 1000BASE-T port (RJ-45 connector) SMC6824FSSC Extender module with one 100BASE-FX single-mode fiber port (SC-type connector) SMC6824FMSC Extender module with one 100BASE-FX multimode fiber port (SC-type connector) SMC6824GB Gigabit module with one slot for GBIC transceivers SMCBGSSCX1 1-por
ORDERING INFORMATION D-2
GLOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3 or better UTP cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 or better UTP cable. 100BASE-FX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two strands of 50/125 or 62.5/125 micron core fiber cable. 1000BASE-T IEEE 802.3ab specification for Gigabit Ethernet over two pairs of Category 5, 5e, or 6 100-ohm UTP cable.
Collision Domain Single CSMA/CD LAN segment. CSMA/CD Carrier Sense Multiple Access/Collision Detect is the communication method employed by Ethernet and Fast Ethernet. End Station A workstation, server, or other device that does not act as a network interconnection. Ethernet A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable. The successor IEEE 802.
IEEE 802.3 Defines carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications. IEEE 802.3ab Defines CSMA/CD access method and physical layer specifications for 1000BASE-T Gigabit Ethernet. IEEE 802.3u Defines CSMA/CD access method and physical layer specifications for 100BASE-TX Fast Ethernet. IEEE 802.3x Defines Ethernet frame start/stop requests and timers used for flow control on full-duplex links. IEEE 802.
Media Access Control (MAC) A portion of the networking protocol that governs access to the transmission medium, facilitating the exchange of data between network nodes. MIB An acronym for Management Information Base. It is a set of database objects that contains information about the device. MII Media Independent Interface, the standard interface for Fast Ethernet—similar to the AUI interface for traditional Ethernet. Network Diameter Wire distance between two end stations in the same collision domain.
INDEX Numerics 10/100 Mbps connectivity rules 4-7 10/100/1000BASE-T modules 1-6 1000 Mbps connectivity rules 4-7 1000BASE-T cable lengths 4-7 1000BASE-X modules 1-7 100BASE-FX connections 4-4 fiber cable lengths 4-7 modules 1-6, 1-7 100BASE-TX cable lengths 4-7 ports 1-3 10BASE-T cable lengths 4-7 ports 1-3 A accessories, ordering D-1 adhesive feet, attaching 3-6 air flow requirements 3-1 application examples 2-2 applications 2-2 collapsed backbone 2-2 VLAN connections 2-5 B brackets, attaching 3-5 buffer
INDEX G Gigabit Ethernet cable lengths 4-7 grounding for racks 3-4 I indicators, LED 1-4 installation connecting devices to the switch 4-2 desktop or shelf mounting 3-6 installing optional modules 3-4 port connections 4-4 power requirements 3-1 problems A-2 rack mounting 3-4 site requirements 3-1 wiring closet connections 4-3 L laser safety 4-5 LED indicators Diag 1-5 Link/Act 1-4 Power 1-5 problems A-1 limited warranty C-4 location requirements 3-1 M management agent 1-2 features 1-10, C-3 out-of-band
INDEX rear panel receptacles 1-8 RJ-45 port 1-3 pinouts B-5 rubber foot pads, attaching 3-6 S sample applications 2-2 SC port connections 4-4 screws for rack mounting 3-3 SC-ST Converter 4-4, 4-6, D-1 site selelction 3-1 SNMP agent 1-2 specifications 1000BASE-X GBIC module C-6 compliances C-4 environmental C-2 physical C-1 power C-2 standards compliance C-4 IEEE C-3 status LEDs 1-4 surge suppressor, using 3-1 switch architecture 1-2 switching, introduction to 2-1 T Telnet A-2 temperature within a rack 3-4
INDEX Index-4
FOR TECHNICAL SUPPORT, CALL: From U.S.A. and Canada (24 hours a day, 7 days a week) (800) SMC-4-YOU; (949) 679-8000; Fax: (949) 679-1481 From Europe (8:00 AM - 5:30 PM UK Time) 44 (0) 118 974 8700; Fax: 44 (0) 118 974 8701 INTERNET E-mail addresses: techsupport@smc.com european.techsupport@smc-europe.com support@smc-asia.com Driver updates: http://www.smc.com/index.cfm?action=tech_support_drivers_downloads World Wide Web: http://www.smc.com http://www.smc-europe.com http://www.smc-asia.