24-Port Fast Ethernet Switch Management Guide

S
YSTEM
D
EFAULTS
1-7
priorities are mapped to a Class of Service value by the switch, and the
traffic then sent to the corresponding output queue.
Multicast Filtering – Specific multicast traffic can be assigned to its own
VLAN to ensure that it does not interfere with normal network traffic and
to guarantee real-time delivery by setting the required priority level for the
designated VLAN. The switch uses IGMP Snooping and Query to manage
multicast group registration.
System Defaults
The switch’s system defaults are provided in the configuration file
“Factory_Default_Config.cfg.” To reset the switch defaults, this file
should be set as the startup configuration file (See “Downloading System
Software from a Server” on page 3-24.)
The following table lists some of the basic system defaults
Table 1-2 System Defaults
Function Parameter Default
Console Port
Connection
Baud Rate auto
Data bits 8
Stop bits 1
Parity none
Local Console Timeout 0 (disabled)