Network Router User Manual

EX500 Serial System EX## - OME0008
- 16 -
3 -6 -3. Power Supply Connector Cable
3 -6 -4. Terminal Plug
When Input Unit Manifold is not required, a Terminal Plug should be hooked up with port C1 ( for SV Valve
Manifold ) or port 0 ( for VQC Valve Manifold ).
Without this plug, the communication LED of GW Unit will not light up.
3 -6 -5. Water Proof Cap
To accommodate the product’s water proof feature, a Water Proof Cap is used for an open port in the GW Unit
and the Input Block. The Cap is supplied with the product when ordered.
Tighten the Water Proof Cap with the specified tightening torque. ( M8 : 0.05 N
m, M12 : 0.1 N
m )
How to Order
E
X
500 -
A
C000 - S
44.7
φ16
M12
Pin assignment
Plug connector
8
2
3
4
5
6
7
1
How to Order
E
X
500 -
A
W
M8 connector ( socket ) / 10 pcs.
M12 connector ( plug ) / 1 pc.
M12 connector ( socket ) / 10 pcs.
TS
ES
TP
Connector
specification
How to Order
EX5 00 -
A
P050
-
S
L : Cable length
S
A
Straight
Angled
010 1m
050 5m
Connector
spesification
Socket connector
Pin assignment
2
43
5
1
1
2
3
4
5
White : 24V DC +10% / -5% ( for solenoid valve )
Black : 24V DC
±
10% ( for power source )
Brown : 0V ( for solenoid valve )
Blue : 0V ( for power source )
Gray : PE
Wiring
Teminal NO.
Cable core
sheath color
M12
31.3
28.3
φ6
30 5
50L
M12
φ14.9
48
34
18
L
φ6
30 5
50
Straight connector type Angled connector type
Electric specification
Rated voltage 125V DC
Rated current 3A
Contact
resistance
( connector part )
40m ohms or less
( At 20mV DC or less, 100mA or less )
Insulation
resistance
1000M ohms or more ( At 500V DC )
Withstand
voltage
( connector part )
1500V AC 1min.
( Leak current 1mA or less )
Electric specification
Rated voltage 36V DC
Rated current 1.5A
Contact
resistance
( connector part )
40m ohms or less
( At 20mV DC or less, 100mA or less )
Insulation
resistance
1000M ohms or more ( At 500V DC )
Withstand
voltage
( connector part )
1000V AC 1min.
( Leak current 1mA or less )
Terminal NO. Cable color / Si
g
nal name
1 Brown 0V ( for solenoid valve)
2 White 24V DC +10% / -5%
( for solenoid valve)
3 Blue 0V ( for power source)
4Black
24V DC ±10%
( for power source)
5Gray PE