- American National Standard Methods of Measurement of the Electromagnetic and Operational Compatibility of Unlicensed Personal Communications Services (UPCS) Devices
- 1. Overview
- 2. Normative references
- 3. Definitions, symbols, acronyms, and abbreviations
- 4. Radiated and conducted emissions test methodology
- 4.1 Test facilities and equipment
- 4.2 Test configurations and setup
- 4.3 Transmitted power and monitoring threshold limits
- 4.4 Limits for radiated and conducted tests
- 4.5 Conducted measurements of products with identical collocated transmitting and monitoring antennas
- 4.6 Conducted measurements of products with collocated transmitting and monitoring antennas of different types
- 4.7 Conducted measurements of products with arbitrarily placed transmitting and monitoring antennas
- 4.8 Radiated measurements of products with identical collocated transmitting and monitoring antennas
- 4.9 Radiated measurements of products with collocated transmitting and monitoring antennas of different types
- 4.10 Radiated measurements of products with arbitrarily placed transmitting and monitoring antennas
- 4.11 Manufacturer’s declarations and descriptions
- 5. Measurement instrumentation
- 6. RF measurements
- 7. Monitoring tests
- 8. Time and spectrum window access procedure
- 9. Test report
- 9.1 Test report contents
- 9.2 Applicable standards
- 9.3 Equipment units tested
- 9.4 Test configuration
- 9.5 List of test equipment
- 9.6 Units of measurement
- 9.7 Location of test site
- 9.8 Measurement procedures
- 9.9 Reporting measurement data
- 9.10 General and special conditions
- 9.11 Summary of results
- 9.12 Required signatures
- 9.13 Test report appendixes
- 9.14 Test report disposition
- Annex A (informative) 47CFR15, Subpart D—Rules and test cases for UPCS devices
- Annex B (informative) Radiated and conducted measurement of power output and monitoring thresholds
- Annex C (informative) Options for implementing the tests of Clause 7 and Clause 8
ANSI C63.17-2006
Methods of Measurement of the Electromagnetic and Operational Compatibility of UPCS Devices
Figure 1
4.2
Table 1
—Test facilities that may be used
Test configurations and setup
Clause 6 provides detailed tests of parameters related to RF emissions, such as peak transmit power,
emission bandwidth, and PSD. Those tests are similar to emission tests performed on most non-UPCS
devices. Clause 7 and Clause 8 provide tests that verify compliance with the monitoring and access
requirements that are unique to UPCS devices. These tests require observation of the electrical performance
characteristics of the EUT in the presence of controlled interference of a specific frequency, power level,
and modulation format. The monitoring and access tests have implications for the conducted and radiated
test setups.
The monitoring antenna refers to the EUT antenna used to monitor the RF signal on the channel prior to
transmission. In many cases, the monitoring antenna will be the same as the transmitting antenna. If it is
not, then the monitoring and access tests are further complicated by the need to ensure that the monitoring
antenna provides “coverage” that is at least equivalent to that which would be provided by the transmit
antenna.
This standard identifies six test configurations. Each configuration is discussed in a separate subclause as
shown in Table 1.
—Test specifications for different antenna configurations
Transmit/monitoring Subclause
Antenna
comparison and
placement
Conducted
measurement based
test (preferred)
Radiated
measurement based
test
Single, or identical collocated 4.5 4.8
Different collocated 4.6 4.9
Arbitrarily placed 4.7 4.10
8
Copyright © 2007 IEEE. All rights reserved.
Licensed to Sid Sanders. ANSI order X_30788. Downloaded 11/19/2007 2:45 PM. Single user license only. Copying and networking prohibited.