TransparencySelect the transparency of the background image ranging from 128~255
ResolutionSet display resolution
ChannelSelect channel number to set encoded output
Region CoverHighlight . Select Area Coverage number button and click Set button to enter
the corresponding channel. User can use the mouse to choose coverage area of any
size (covered areas for video output are displayed as dark blocks);
Time Display and Channel Title set the display position for Time Title and Channel Title.
4.4.6 PTZ Settings
Figure 4.28 PTZ Settings
ChannelSelect input channel for dome camera
ProtocolSelect proper dome camera protocol for corresponding brand and model (e.g.
PELCOD)
AddressSet address for the corresponding dome camera. The default is 1NoteThe address
set here must match the dome camera address or the dome camera cannot be
controlled);
Baud Rate Select the dome camera baud rate to control PTZ and camera on the corresponding
channel. The default is 115200
Data BitsAvailable options: 5-8. The default is 8 bits
Stop BitsTwo options are 1 and 2. The default is 1