Installation Instructions
3
• DO NOT installing panel siding with brushstroke running in 
di erent directions. 
(Figure 3D)
N I - D  S
•     Penetrate  structural  framing  or  wood  structural  panels  and 
 structural framing a minimum of 1-1/2 inches (38 mm). 
•  A reduction in allowable racking shear capacity is required in 
Table 1 of both 
PR-N124 and ESR-1301 when using panel siding 
with a shiplap edge. 
•  For 38 Series panel
 double nailing 
 procedure meets 
     wall bracing 
 requirements for 
 5/16 CATEGORY 
 shear wall design
 value in Table 1.
•  For 76 and 190 Series 
 panel single nailing 
 procedure meets 
 wall bracing
 requirements for 
 5/16 CATEGORY 
 shear wall design 
 value in Table 1. To 
 meet the equivalent 
 3/8 CATEGORY shear
 wall design value, 
 double nailing
 must be used.
•  Align the overlap edge        
  of the panel to the 
    outside  edge  of  the 
  alignment bead on 
 the underlap edge 
    of  the  adjacent  panel 
 as shown in Figure 3B.      
               -      Doing  so  will 
   maintain the 
                          1/8"  (3  mm) 
   expansion gap 
Figure 3D
1/8" 
(3 mm)
gap
Figure 3C
SMOOTH FINISH Brushstroke Texture - NOT Parallel
SMOOTH FINISH Brushstroke Texture - Parallel
Brushstroke direction
Brushstroke direction
Brushstroke direction
Brushstroke direction
Brushstroke direction
Brushstroke direction
Brushstroke 
direction
Brushstroke 
direction
SMOOTH FINISH P O 
(CONT.) 
Single row of nails
3/8" (10 mm)
from edge
Double row of nails
1" (25 mm) 
from edge
1/8" 
(3 mm) 
gap
Alignment
bead
Alignment
bead
min. 1-1/2"
(38 mm)
embedment
min. 1-1/2"
(38 mm)
embedment
 on the back side of the panel seam.   
 - DO NOT INSTALL OVERLAP EDGE ON TOP OF UNDERLAP  
   ALIGNMENT BEAD.
•  
Where siding butts window trim, door casings and masonry,   
 etc. leave a 3/16 inch gap and seal.
• Smooth fi nish square edge panel siding may be installed in 
either the horizontal or vertical orientation. 
- For a consistent fi  nish  appearance,  maintain  the  same   
   panel orientation throughout the installation.   
 (Either all panels installed vertical or horizontal.)
• Smooth fi nish panels have a subtle brushstroke texture, this 
texture runs parallel to the long panel direction and can be used 
to identify the panel orientation even after the panels have 
been reduced in size. 
- See photos with directional arrows to familiarize yourself 
 with this feature before beginning installation. 
(Figure 3C) 
SMOOTH FINISH P O 
Figure 3A
Figure 3B