User's Guide
16
How to Pair a Remote Tag by the Panel
Go to Menu>Parts>Remote>Add and enter.
You need to enter a digit from 0 to 9 to designate a unique number
for the remote tag to be paired.
Synchronizing is shown, the hub goes into the paring mode and
count down the pairing time remaining.
Press any button of remote tag to send a transmission signal to the
hub.
As the serial number of remote tag is added to the hub, Leaning OK
will be shown.
The hub will show Device code has been learned if serial number
of remote tag have been paired.
Go to Menu>Parts>Remote>Delete to delete the remote tag specified by serial number .
Go to Menu>Parts>Remote>Delete All to delete all the remote tags. Total number of paired remote
tags is shown before deleting.
How to Pair a Wireless Sensor by Panel
(Door/Window Sensor or PIR Motion Detector)
Go to Menu>Parts>Detector>Add and enter.
Scroll to to select the desired Zone Name.
Scroll to to select the desired Zone Mode(Type).
You must assign a Zone Mode to each zone(sensor), which defines
the way in which the system responds to faults in that zone.
Normal: Sensors set to Normal Zone are activated in Arm (full arm)
or STAY Mode (partial arm). We recommend setting door/window
sensor to Normal Zone.
24H: Sensors set to 24H Zone will activate the alarm and sounding
when triggered, regardless of the alarm status (Armed or Disarmed).
Delay: If sensors set to Delay Zone are triggered, the Hub will sound
the alarm after the delay time passed. We recommend setting door
sensors with a delay if they are used as primary entryways.
Home: Sensors set to Home Zone are only activated in Arm (full
arm). If Stay Arm Mode (partial/home arm) is used, these sensors
are not armed and will not activate the alarm if triggered. We
recommend setting PIR Motion Detectors to Home Zone.
24H mute: The mode is same as 24H but sound.
To be used as doorbell, select Doorbell.
Scroll to and tap ► to enable keypad, use the digits keypad
to enter Zone Number (0-89 are available) which should be
unique if more than one sensor needs to be paired, then tap √ to
to enter.
Select √ , Synchronizing is shown, the panel goes into the
paring mode and count down the pairing time remaining.
Trigger wireless sensor to send a transmission signal to the
panel as shown on the right.
As the serial number of wireless sensor is added to the panel,
Leaning OK will be shown.
The system will show Device code has been learned if serial
number of this wireless sensor has been paired, and Zone
Name/Mode/Number will be refreshed.
Go to Menu>Parts>Detector>Edit to edit Zone Name/Zone Mode of selected zone specified by the
zone number, or delete the selected zone.
Go to Menu>Parts>Detector>Delete All to delete all the wireless sensors. Total number of paired
sensors is shown before deleting.
Press the panic button
or separate the sensor
from the magnet by at
least 1.0 inches(2.5 cm)
Press the pairing button or
place the PIR motion
detector in a high position
and then walk within the
detection area to trigger the
PIR alarm once (the
indicator light flashes once)
Set Name/Mode/Number
Door Alarm
24H mute
1
24h