User Manual Version 1.0.0
SMARTICO LLC. Page 9 of 15
Table 5: Internal Communication Interface pinout
Pin
Name
Type
Description
1
VDD
VDD
V+ supply voltage
2
PRG_1
-
Factory programming pin 1
3
PRG_2
-
Factory programming pin 2
4
NRST
Input
MCU Reset
5
UART_TX
Output
UART transmit data output of the sensor
6
UART_RX
Input
UART receive data input of the sensor
7
GND
GND
Ground
8
DBG
Output
Factory debug pin
4 Initial Setup
4.1 Device activation
Smartico Industrial Sensor LoRaWAN may be in one of the following Device Operating Modes:
SERVICE: in this mode, various service operations can be performed with the device. Service operations
are performed by the manufacturer and are not described in this document.
ON READY: the device is in normal mode, but no activity is taking place in the radio air. In other words,
the radio part is disabled in this mode. Sensor can be switched to this mode before long-term storage.
ON AIR: normal operating mode of the device, in which data is transmitted via the LPWAN network. The
SENSOR can be switched to this mode by command or by the influence of a magnetic field in the when it
ON READY mode. Also, the sensor is switched to this mode after 30 minutes of inactivity in the SERVICE
mode.
If the device has all the preset settings, then it can be put into operation with a magnet, even without opening the
housing. The place where you need to bring the magnet is shown in the Figure 4.
Note: Hold the magnet for at least 40 seconds.