Quick-Start Guide
Partition Select Button
PowerMax & MKP-150/151 Keypad
Arming multiple partitions
Arm or Disarm as without partitions
•
All partitions associated with the user code are Armed or Disarmed
•
Arming a specic partition
Press
1.
LCD will show 2. SELECT PARTITION
Press 3. 1, 2, or 3 to select the partition
Press
4. / (Arm) or (Disarm)
MCT-237 Two-way Keyfob
Arming multiple partitions
Pressing the arming buttons without selecting an individual
•
partitionArms/Disarmsalldenedpartitions.
Arming a specic partition
Press
1.
In the LCD display, a digit 2. [ P1:- P2:- P3:-] will light to
indicate the currently selected partition
Repeated pressing of
3. selects the following partitions
Press
4. / or within 5 seconds
What are Common Areas?
Consider the reception area in the example of the accountants
and solicitors:
Neitherofceownerwantsthereceptionareatobearmeduntil
•
bothofcesarearmedsothatevenifoneofceisoccupied(his
ofcepartitionisdisarmed),thereceptionareamustbedisarmed
This is called a
•
Common Area
Common Areas are used as walkthrough zones to multiple
partitions
There may be more than one
•
Common Area
in an installation
depending on the layout of the property
A
•
Common Area
is NOT the same as a partition:
It cannot be armed/disarmed directly
•
Common Area zones behave according to the state of the
•
partitions sharing the Common Area.
Dening Common Areas
A
•
Common Area
isdenedbyassigningmorethanone
partition to a zone or a group of zones.
Example:
Accountants’detectorisassignedtotherstPartition
•
Solicitors’ detector is assigned to the second Partition
•
Reception area’s detector is assigned to both partitions and
•
forms a common area
Accountants
Reception
Partition 1
Common area
Partition 2
Solicitors
How Zones in Common Area Behave
Zones in common areas behave according to the partition
which is the “least secure”
24hrs zones
Are always armed
•
Perimeter zones
Armed when all partitions they are assigned
•
to are either HOME or AWAY
Disarmed if at least one partition to which
•
they are assigned to is disarmed
Interior zones
Armed when all partitions they are assigned
•
to are AWAY
Disarmed if at least one partition to which
•
they are assigned to is HOME or disarmed
Partition Select Button