Partitions II
What Are Partitions?
The PowerMax includes an optional partition feature.
•
Partitioning allows you to have up to three independently
controllable areas whereby each can be in the HOME, AWAY
or DISARM state.
Each independent area is called a ‘partition’ and has its own
•
denedzones,usercodes,etc.
Partitions provide highly exible control in premises
•
where multiple areas need to be monitored or secured
independently.
Using Partitions in the Workplace
Theareainthisexamplehas2ofces(accountant’sandsolicitor’s)
•
Eachofcerunsindependentlywithdifferentworkinghours
•
Thereceptionareaissharedbybothofces
•
Each area has a NEXT motion detector installed•
The reception area is explained later in the ‘ L
common area
’
section
STEP 1: Planning & Enabling
The panel comes with partitioning feature disabled.
•
TherststepistoenablePartitionsIIfeature:
•
From the
•
INSTALLER MODE select PARTITIONING and
press
Select
•
ENABLE and press twice
To avoid confusion and to make installation simpler, it is rec- L
ommended to note down the zones and their corresponding
partitions
STEP 2: Dening Partitions
Partitioning programming is performed via the
•
DEFINE ZONES
menu.
For each zone, set the zone type, name and chime option, as
•
per the installer manual.
Select the
•
PARTITION option (follows CHIME)
The screen will display
•
[P1:- P2:- P3:-] Black squares indicate
the partitions to which the current zone is assigned.
Assign the zone to its proper partition or partitions
•
(1, 2, or 3).
To select partitions simply press
•
, or on the keypad
respectively.
Press
•
twicetoconrmthesettings.
A zone must be assigned to at least one partition at all times L
STEP 3: Setting User Codes & Keyfobs
User code 1 is the master user code and controls all 3 partitions.
•
Otherusercodescancontrolonlyaspecicpartitionoracombi-
•
nationofpartitionsdenedbythemasteruserduringsetup.
Afterselectinganddeningusercodes,selectthe
•
ACCESS TO
PART menu to associate the user code with a partition or a
partition combination.
Keyfobs are associated with a partition or
•
a partition combination during enrolment,
performed via the ENROLLING menu.
To change the partition association of L
keyfobs simply re-enroll the keyfob
Arming and Disarming the System
A user, using a user code or an MCT-237 two-way keyfob,
•
can control all partitions associated with the code or keyfob
simultaneously, or an individual partition
When using MCT-234 keyfob or the MCM-140 remote
•
commander, a user can only control all the associated partition(s)
simultaneously (i.e. no control over individual partitions).
MCT-237 MCM-140/+ MKP-150MCT-234
Accountants
Reception
Partition 1
Common area
Partition 2
Solicitors