Full Product Manual

GP Series
16
©2013 Smarter Tools, Inc. All Rights Reserved
Operation
______________________________________________________________________________________________
Starting
1. Make sure the generator is on a flat and level
surface.
2. Make sure the electrical powered
tools/equipment that will be used are not
plugged into the generator while the engine is
started.
3. Turn the fuel valve to the “ON” position.
4. Pull the choke rod out.
5. Turn the engine power switch to its “ON”
position.
6. For “Electric Start” models (‘E’ and EB’), turn
key to the start position and hold until engine
starts. If the engine fails to start within 5
seconds, release the key and wait at least 10
seconds before attempting to start the engine
again.
7. For “Recoil Start”, hold the start handle loosely
and pull it slowly several times to allow the
gasoline to flow into the engine’s carburetor.
Then hold the start handle firmly and pull the rope
hard and fast. Pull the rope all the way out, using two
hands if necessary. If necessary pull the rope
several times until the engine starts.
8. Allow the engine to idle until warm. The choke will
turn itself off with the vacuum control as the motor
warms up. Check to make sure the choke rod in all
the way.
Note: If the engine starts but does not run, make certain
that the generator is on a flat, level surface. The
engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level
falls below a critical threshold.