User Manual

24
Traceability control system PC software
8-2) Reading and writing of maintenance data
Call the data from the torque wrench.
1) Remove the work data in the torque wrench.
Menu bar Communication Data deletion Data deletionicon
Work and measurement data will be deleted in the torque wrench.
2) Reads data
Menu bar Communication Reads data Reads dataicon
Maintenance information of the torque wrench is loaded.
3) Writing of maintenance data
Menu bar Communication Writing of data Writing of dataicon
Maintenance information to the torque wrench is written.
8-3) Description of maintenance data
1) Wrench name
Sets a name for each torque wrench (up to 8 alphanumeric characters).
2) Verify mode (Only for HTW)
It can be measured in the usual < lower torque > below.
It can be set in the 10% to 90 % of the value for the < lower torque >.
Record the peak value after exceeding the set value (%).
3) On-line coordination < Wireless communication mode >
Individual: Tightening can be performed without confirmation from the PC after torque
data has been sent out in wireless communication mode.
Coordinate: The torque wrench will be on standby until receiving confirmation from the
PC after torque data has been sent out in wireless communication mode.
4) Wireless settingCordless handsetTorque wrench setting
(1) Wireless CH CHIt will be all 16CH of up to 11 to 26
(2) Wireless ID A unique <ID> number that identifies the torque wrench.
5) Wireless settingReceiverWireless receiver setting
Wireless CH After setting, please do write in the "master channel setting" button.
6) Over torque alarm function (Only for HTW)
Default: When torque data has exceeded <Upper torque>, the buzzer and the vibrating alert
are activated for the specified time.
Continuation: When torque data has exceeded <Upper torque>, the buzzer and the vibrating
Point
In case of different channel, you can set the same ID number.
Point
1), 2) of the order is required.