Maintenance Guide

C H A P T E R 2
Installing your room system’s hardware
10 smarttech.com/kb/170450
l Ensure the wall can support the weight of the room system.
Room Weight (lb.) Weight (kg)
Small 271 123
Medium 312 141.6
Large 520 236
N O T E S
o
Refer to local building codes to confirm that the wall can support the above weights.
o
Refer to the hardware selection guide for the recommended hardware for your wall type
(see Installation instructions on page 8).
l Choose an appropriate location for the room system:
o
Do not install the room system in a location where a door or gate could hit it.
o
Do not install the room system in an area where it will be subjected to strong vibrations or
dust.
o
Do not install the room system where the main power supply enters the building.
o
Ensure adequate ventilation or provide air conditioning around the room system so that heat
can flow away from the unit and the mounting equipment.
o
If you mount the room system in a recessed area, leave at least 4" (10 cm) of space
between the room system and the recessed walls to enable ventilation and cooling.
l Install the room system so that its center aligns with the center of the meeting room table. This
ensures the meeting room table appears in the center of the camera’s field of view.
l Install the room system so that the interactive flat panels are the appropriate distance from the
floor.
Distance Small room Medium room Large room
From the floor to the bottom of the
interactive flat panel
32" (81.4 cm) 29 1/2" (74.9 cm) 32" (81.4 cm)
From the floor to the bottom of the
active display area
38 1/8" (97 cm) 35 3/8" (89.9 cm) 38 1/8" (97 cm)