bmp280 datasheet
Table Of Contents
- 1. Specification
- 2. Absolute maximum ratings
- 3. Functional description
- 4. Global memory map and register description
- 5. Digital interfaces
- 6. Pin-out and connection diagram
- 7. Package, reel and environment
- 8. Appendix 1: Computation formulae for 32 bit systems
- 9. Legal disclaimer
- 10. Document history and modification
Bosch
Sensortec | BMP280 Data sheet
30 |
48
Modifications reserved | Data subject to change without notice
Document number: BST-BMP280-DS001-23 Revision_1.23_11202
0
The SPI interface uses the following pins:
• CSB: chip select, active low
• SCK: serial clock
• SDI: serial data input; data input/output in 3-wire mode
• SDO: serial data output; hi-Z in 3-wire mode
Refer to chapter 6 for connection instructions.
CSB is active low and has an integrated pull-up resistor. Data on SDI is latched by the device at SCK
rising edge and SDO is changed at SCK falling edge. Communication starts when CSB goes to low
and stops when CSB goes to high; during these transitions on CSB, SCK must be stable. The SPI
protocol is shown in Figure 9. For timing details, please review Table 28.
CSB
SCK
SDI
RW
AD
6
AD5
AD4
AD3
AD2
AD1
AD0
DI5
DI4
DI3
DI2
DI1
DI0
DI7
DI6
SDO
DO5
DO4
DO3
DO2
DO1
DO0
DO7
DO6
tri-state
Figure 9: SPI protocol (shown for mode ‘11’ in 4-wire configuration)
In SPI mode, only 7 bits of the register addresses are used; the MSB of register address is not used
and replaced by a read/write bit (RW = ‘0’ for write and RW = ‘1’ for read).
Example: address 0xF7 is accessed by using SPI register address 0x77. For write access, the byte
0x77 is transferred, for read access, the byte 0xF7 is transferred.
5.3.1 SPI write
Writing is done by lowering CSB and sending pairs control bytes and register data. The control bytes
consist of the SPI register address (= full register address without bit 7) and the write command (bit7 =
RW = ‘0’). Several pairs can be written without raising CSB. The transaction is ended by a raising
CSB. The SPI write protocol is depicted in Figure 10.
Start
RW RW Stop
0 1 1 1 0 1 0 0 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 0 1 1 1 0 1 0 1 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
Control byte
CSB
=
1
Data byte
Register address (F5h)
Data register - adress F5h
Register address (F4h)
CSB
=
0
Control byte
Data byte
Data register - address F4h
Figure 10: SPI multiple byte write (not auto-incremented)
5.3.2 SPI read
Reading is done by lowering CSB and first sending one control byte. The control bytes consist of the
SPI register address (= full register address without bit 7) and the read command (bit 7 = RW = ‘1’).
After writing the control byte, data is sent out of the SDO pin (SDI in 3-wire mode); the register address
is automatically incremented. The SPI read protocol is shown in Figure 11.