bmp280 datasheet
Table Of Contents
- 1. Specification
- 2. Absolute maximum ratings
- 3. Functional description
- 4. Global memory map and register description
- 5. Digital interfaces
- 6. Pin-out and connection diagram
- 7. Package, reel and environment
- 8. Appendix 1: Computation formulae for 32 bit systems
- 9. Legal disclaimer
- 10. Document history and modification
Bosch
Sensortec | BMP280 Data sheet
17 |
48
Modifications reserved | Data subject to change without notice
Document number: BST-BMP280-DS001-23 Revision_1.23_11202
0
The standby time is determined by the contents of the t_sb[2:0] bits in control register 0xF5 according
to the table below:
Table 11: t_sb settings
t_sb[1:0] t
standby
[ms]
000
0.5
001
62.5
010
125
011
250
100
500
101
1000
110
2000
111
4000
3.6.4 Mode transition diagram
The supported mode transitions are displayed below. If the device is currently performing a
measurement, execution of mode switching commands is delayed until the end of the currently
running measurement period. Further mode change commands are ignored until the last mode
change command is executed. Mode transitions other than the ones shown below are tested for
stability but do not represent recommended use of the device.
Power OFF
(V
DD
or V
DDIO
= 0)
V
DD
and V
DDIO
supplied
Mode[1:0] = 00
Mode[1:0] = 01
Sleep
Normal
(cyclic standby and
measurement periods)
Mode[1:0] = 11
Forced
(one measurement
period)
Mode[1:0] = 01