LM339DR Datasheet

LM139-N
,
LM239-N
,
LM2901-N
,
LM3302-N
,
LM339-N
www.ti.com
SNOSBJ3E NOVEMBER 1999REVISED DECEMBER 2014
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
LM139N, LM239N, LM339N, LM2901N 2 36
Single Supply
LM3302N 2 28
Supply Voltage V
LM139N, LM239N, LM339N, LM2901N ±1 ±18
Dual Supply
LM3302N ±1 ±14
LM139/LM139A 55 125
LM2901/LM3302 40 85
Operating Temperature °C
LM239/LM239A 25 85
LM339/LM339A 0 70
6.4 Thermal Information
LM139-N, LM2901-N, LM2901-N,
LM239-N, LM339-N LM339-N
LM339-N
THERMAL METRIC
(1)
UNIT
J D NFF
14 PINS
R
θJA
Junction-to-ambient thermal resistance 95 95 95 °C/W
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
Copyright © 1999–2014, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: LM139-N LM239-N LM2901-N LM3302-N LM339-N