Office/Office TBF Series Uninterruptible Power Supply 400VA / 600VA OFFICE-TBF Series USER'S GUIDE P.N.16001400 Rev.
Important Safety Instructions Save These Instructions CAUTION!!! Please read the following information carefully and save this manual for future reference. Ignoring these safety warnings may endanger your life or health, as well as the function of the equipment and safety of your data. Risk of Electric Shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Risk of Electric Shock. This unit receives power from more than one source.
Important Safety Instructions Save These Instructions NOTICE!!! The output of the Office 400 is not sinusoidal. It has a total harmonic distortion of 61% and a maximum single harmonic distortion of 46.6%. The output of the Office 600 is not sinusoidal. It has a total harmonic distortion of 46% and a maximum single harmonic distortion of 33%.
System Description Top View: 1. Power On/Off Switch 2. Green LED: On AC Line Mode 3. Amber LED: Battery Mode 4. Red LED: Fault 5. Surge protected only receptacle 6. Battery power supplied receptacles SmartPower • • • • • • • • • • • • • • • • SYSTE MS REAR VIEW OF400-OF600 Rear View: 7. AC input 8. Telephone Line Protection 9. DB9 (RS-232) Interface RS232 REAR VIEW OF400USB-OF600USB Rear View (USB Model): 7. AC input 8. Network/Phne Line Protection 9. DB9 (RS-232) Interface 10.
Troubleshooting If the UPS failed to operate properly, please review the following: Symptom Possible Cause Solution Green LED is "ON", 1. UPS is not connected 1. Connect the UPS but audible alarm is properly to the main power. according to the installaheard intermittently. 2. Line breaker protected tion guide. 2. Press the breaker. UPS is functioning UPS is overloaded. but audible alarm is heard continuously Verify that the load matches the UPS capacity specified in the spec.
Installation and Operation Installing the Office Series UPS is as easy as following the steps shown. Be aware that the Power Switch must be kept in the "ON" position and all equipment must be plugged into the "Battery Power Supplied" receptacles. Otherwise the UPS will be disabled and your equipment will not be protected during a power failure. 1 Inspection Unpack the UPS carefully and note the packing method. Retain the box and packing material for possible future shipment.
3 Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8-10 hours with no load (no electrical devices such as computers, monitors, etc.) connected.
5 Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the serial cables as shown in the diagram below. REAR VIEW OF400-OF600 DB9 (RS232) port RS232 PC 6 DB9 (RS232) port Tel/Modem/DSL Connection Plug incoming telephone/DSL line into the "in" socket at the rear panel of the Office Series UPS. Use the provided telephone cord and plug one end to the "Out" socket at the rear panel of the UPS.
7 USB Connection with Network Protection (OF-USB models only) To allow for unattended system shutdown for your operating system, connect the USB cable as shown in the diagram below. To protect the Network connection, plug incoming Network line into the "in" socket at the rear panel of the Office-USB Series UPS. Use provided CAT5 Network cable and plug one end to the "Out" socket at the rear panel of the UPS. Plug the other end of the Network socket of the PC as shown below.
DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. 11 Green Power Function 12 Battery Replacement All Office Series UPS are equipped with Green Power Function. If no load connects to the UPS, it will automatically shut down in 5 minutes for energy saving during power failure. The UPS will restart while AC recovery.
Free Software Download SmartPower Systems provides a complete line of software solutions for standalone and networked computers, including SNMP support.
Specifications - 400VA/600VA MODEL OF400 OF400USB OF600 OF600USB OUTPUT Capacity VA / W 400 / 200 600 / 300 Voltage (on battery) 120VAC ±10% Simulated sinewave Frequency (on battery) 50/60Hz ±1Hz 4 milli seconds, including detection time Transfer Time INPUT Voltage 120 VAC - 20% +15% Frequency 50/60Hz ±3Hz (auto sensing) PROTECTION & FILTERING Spike Protection 300 Joules Overload and Short Circuit Protection Electronic Tel / Fax / Modem / DSL / Network Communication Port RJ11 RJ11/45
Specifications - 400VA/600VA MODEL OF400-TBF OF400USB-TBF OF600-TBF OF600USB-TBF OUTPUT Capacity VA / W 400 / 200 600 / 300 Voltage (on battery) 120VAC ±10% Simulated sinewave Frequency (on battery) 50/60Hz ±1Hz 4 milli seconds, including detection time Transfer Time INPUT Voltage 120 VAC - 20% +15% Frequency 50/60Hz ±3Hz (auto sensing) PROTECTION & FILTERING Spike Protection 1020 (Joules) Overload and Short Circuit Protection Electronic <10V Normal Mode (L-N) <0.
LIMITED PRODUCT WARRANTY We warrant this product to be free from defects in material and workmanship for 2 years. The battery has a 4 year pro-rated warranty. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product. Visit our website for details www.smartpowersystems.com/New/support.
™ SmartPower • • • • • • • • • • • • • • • • SYSTEMS 1760 Stebbins Dr. • Houston, TX 77043 1-800-882-8285 • URL:www.smartpowersystems.com Email:support@smartpowersystems.