Sunny Boy Installation Manual

Table Of Contents
10 Technical Data
SMA Solar Technology AG
Installation ManualSBxx-1SP-US-41-IA-xx-1068
SB6.0-1SP-US-41 SB7.0-1SP-US-41 SB7.7-1SP-US-41
Maximum apparent
AC power at 208V
5200VA 6650VA 6650VA
Maximum apparent
AC power at 240V
6000VA 7000VA 7680VA
Rated grid voltage 208 V / 240 V 208 V / 240 V 208 V / 240 V
AC voltage range at
208V
183V to 229V 183V to 229V 183V to 229V
AC voltage range at
240V
211V to 264V 211V to 264V 211V to 264V
Nominal AC current at
208V
25 A 32 A 32 A
Nominal AC current at
240V
25A 29.2A 32A
Maximum output cur-
rent at 208V
25A 32 A 32 A
Maximum output cur-
rent at 240V
25A 29.2 A 32 A
Total harmonic factor
of output current
<4% <4% <4%
Maximum residual out-
put current
30.4A 30.4 A 30.4A
Duration of the maxi-
mum residual output
current
250ms 250ms 250ms
Line synchronization
characteristics/inrush
current
Method 2/2.4A Method 2/2.4A Method 2/2.4A
Rated power frequency 60 Hz 60 Hz 60 Hz
Operating range at AC
power frequency
60Hz
59.3Hz to 60.5Hz 59.3Hz to 60.5Hz 59.3Hz to 60.5Hz
Output power at
+60°C (+140°F)
> 3300W >6700W >6700W
Power factor at rated
power
1 1 1
ENGLISH