Installation Guide
SMA America, LLC 7 Commissioning
Installation Manual SB3-5TLUS22-IA-en-16 49
7.1.2 Changing the Country Data Set and the Display Language
If the default country data set of the inverter does not apply to your country, you must change the
country data set and the display language.
1. If the inverter is in operation, disconnect it (see Section 10).
2. Set the rotary switches A and B to the desired
position using a flat-blade screwdriver
(blade width: 2.5 mm) (see Section7.1.1
"Overview of the Rotary Switches", page47).
3. Commission the inverter (see Section 7.2).
☑ The inverter will adopt the setting after commissioning. This can take up to 5 minutes.
D 2 Island mode 60 Hz French
D 3 Island mode 60 Hz Spanish
D 4 Island mode 60 Hz Italian
D 5 Island mode 60 Hz Greek
D 6 Island mode 60 Hz Czech
E 0 Island mode 50 Hz English
E 1 Island mode 50 Hz German
E 2 Island mode 50 Hz French
E 3 Island mode 50 Hz Spanish
E 4 Island mode 50 Hz Italian
E 5 Island mode 50 Hz Greek
E 6 Island mode 50 Hz Czech
* The country data set is automatically blocked after ten feed-in hours. Then you can only change the country data set by
entering the personal access code you received from SMA on a communication device.
Rotary switch A
position
Rotary switch B
position
Country data set Display language