User manual
1. Use as directed:
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V ~50Hz.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
If these points named above are not adhered to, a short circuit or
electrical shock may occur!
2. Technical Data:
Operating voltage: 230V ~50Hz
Safety class: I
Safety type: IP 23
Bulb: QPAR51, GU10, max. 35W
Dimensions (L/W/H): 7/7/13,8 cm
Weight: 0,4 kg
Importeur: SLV Elektronik GmbH
IP 23: Protection against foreign objects > Ø 12,5mm – Protection against
spraying water up to 60° to the vertical.
3. Installation
The electric connection may be executed only by an electric expert
who is familiar with the valid directives!
Attention: Switch off the power of the mains supply line or
respectively of the connection lead before doing any works
.
Use only
parts, which are supplied with the product or are described as accessories!
Otherwise the product or the installation might not be sufficiently safe.
Installation place:
The product is suited for ceiling installation.
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
The light exit should be placed at least so far from the illuminated surface,
as indicated as minimum distance on the type plate of the luminaire:
0,5
m
. Pay special caution to easily inflammable objects (e.g. foliage).
Separate Installation Steps
Remove the mounting plate from the housing by loosening the two
screws on the side of the canopy.
Determine the place of installation and mark the holes to be drilled. Note
that the cable outlet of the mains supply corresponds with the cable inlet
of the fixture. Do not damage the power supply line, e.g. by drilling,
screws or strong bending.
Fasten the mounting plate to the mounting surface.
Electrical Connection
The product must be able to be separated by an all pole separation from
the current supply.
For electric connection attach the black or brown wire (live conductor) of
the mains supply with the clamp L and the blue wire (neutral conductor)
of the mains supply with the clamp N. The green-yellow wire (protective
conductor) of the mains supply has to be tightly screwed into the earth
clamp
of the product.
Inserting the bulb: Insert the bulb with a quarter-turn to the right.
Now fasten the housing back on the mounting plate. Do not forget to
apply the toothed washers!
Ensure that the light fixture holds securely!
The product is now ready for operation.
4. Operation
:
Information for the user:
Operate the product only if it is working correctly. Switch off the product
with a malfunction immediately and operate it again only after examination
by an electrical specialist. This is the case, when:
visible damages appear.
the product does not work.
smoke, steam or crackling sounds appear.
an overheating is recognisable.
Repairs of the product or work on mains voltage-prominent sections may
only be carried out by qualified electricians.
Attention: Here exists mortal danger from an electric shock!
How to avoid failure and fire risk:
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no decoration.
Never let children play unsupervised with electric products! Children
can not always estimate dangers in dealing with electric energy correctly.
The following enviromental influences may have unwanted effects on
the surface of the product:
ENG
Instruction Manual for THEO GU10 OUT
acid rain and sour soil high salt content in the air
thawing salt cleaning agents
other chemical substances (e.g. herbicides)
Protect the product by adequate means to avoid unwanted changes of the
surface. Cleaning tip: Switch off power! Clean the product with a damp
cloth.
What is to do if a bulb is defect or does not work?
Disconnect the product from power, before you exchange the bulbs.
Caution: Let the bulb cool down first before replacement – otherwise
considerable risk of injury exists because of the hot surface.
Replace the bulbs only with bulbs of the same data like socket, power
and capacity. Every other sort of bulb can lead to damages of the light.
Replacing the bulb: see Installation.
LN
5. What else has to be considered?
Disconnect the product from power, before you…
clean or maintain the product.
do any works on the product or its components (electric expert).
229584 12/2005 by SLV Elektronik GmbH
Technical Details are subject to change. Duplication prohibited !
F
Mode d'emploi pour
THEO GU10 OUT
1. A utiliser comme indiqué :
Ce produit ne sert qu’à éclairer:
il est prévu pour une tension de 230V ~50Hz.
il ne doit être soumis ni aux efforts mécaniques importants ni à un
encrassement important.
il ne doit être utilisé qu’après examen si le produit a été stocké dans un
entrepôt humide ou sale.
il ne doit pas être modifié.
Un non-respect de ces points peut causer un court-circuit ou une
décharge électrique!
2. Informations techniques:
Tension d'alimentation: 230V ~50Hz
Classe de protection: I
Degré de protection: IP 23
Ampoule: QPAR51, GU10, max. 35W
Dimensions (L/L/H): 7/7/13,8 cm
Poids: 0,4 kg
Importeur: SLV Elektronik GmbH
IP 23: Protection contre les corps étrangers durs > 12,5mm - Protection
contre l’eau vaporisée venant de la verticale jusqu’à 60°.
3. Installation
La connection électrique doit être exécutée par un professionnel,
lequel est familier des normes en vigueur!
Attention: Mettez l’alimentation électrique ou le raccordement au
secteur hors tension avant de travailler!
Utilisez seulement des pièces qui ont été livrées avec le produit ou qui sont
uniquement décrites comme accessoires ! Sinon, l’installation ainsi que le
produit ne peuvent pas être garantis.
Lieu d'installation
Ce produit est fait pour un montage au plafond. Veillez à ce que le produit
soit monté de manière stable et résistante au basculement.




