User manual

1. Use as directed:
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V ~50Hz.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
If these points named above are not adhered to, a short circuit or
electrical shock may occur!
2. Technical Data:
227174/75/76 227184
Operating voltage: 230V ~50Hz 230V ~50Hz
Safety class: I I
Safety type: IP 54 IP 54
Bulb: TC-TSE, E27, 25W TC-D(T), G24d-2,
18W
Dimensions (L/W/H): 29,5/13,5/13cm
Weight: 1,6 kg
Importeur: SLV Elektronik GmbH
IP 54: Protection against disturbing dust deposition - Protection against
splashing water from all directions
3. Installation
The electric connection may be executed only by an electric expert
who is familiar with the valid directives!
Attention: Switch off the power of the mains supply line or
respectively of the connection lead before doing any works
. Use only
parts, which are supplied with the product or are described as accessories!
Otherwise the product or the installation might not be sufficiently safe.
Installation place:
The product is suited for wall and ceiling installation.
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
Install a reactive current compensation when operating several fixtures on
one circuit.
Separate Installation Steps
Remove the housing from the mounting plate (1).
Determine the place of installation and mark the holes to be drilled. Note
that the cable outlet of the power supply line fits between the mounting
bracket and the canopy. Do not damage the power supply line, e.g. by
drilling, screws or strong bending.
Direct the mains lead through the rubber gasket (2).
Fasten the mounting plate to the mounting surface (3).
Electrical Connection
The product must be able to be separated by an all pole separation from
the current supply.
Equip the wire ends with the supplied protective tubes (4)
For electric connection attach the black or brown wire (live conductor) of
the mains supply with the clamp L and the blue wire (neutral conductor)
of the mains supply with the clamp N. The green-yellow wire (protective
conductor) of the mains supply has to be tightly screwed into the earth
clamp
of the product (5).
Inserting the bulb: TC-TSE: Screw the bulb into the socket. TC-D(T):
Stick the bulb into the socket.
Put the housing back on and fix it.
Ensure a secure fit of the fixture.
The product is now ready for operation.
4. Operation
:
Information for the user:
Operate the product only if it is working correctly. Switch off the product
with a malfunction immediately and operate it again only after examination
by an electrical specialist. This is the case, when:
visible damages appear.
the product does not work.
smoke, steam or crackling sounds appear.
an overheating is recognisable.
Repairs of the product or work on mains voltage-prominent sections may
only be carried out by qualified electricians.
Attention: Here exists mortal danger from an electric shock!
How to avoid failure and fire risk:
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no
decoration.
Never let children play unsupervised with electric products! Children
can not always estimate dangers in dealing with electric energy correctly.
What is to do if a bulb is defect or does not work?
Disconnect the product from power, before you exchange
the bulbs.
Caution: Let the bulb cool down first before replacement –
otherwise considerable risk of injury exists because of the hot
surface.
Replace the bulbs only with bulbs of the same data like socket,
power and capacity. Every other sort of bulb can lead to
damages of the light.
Replacing the bulb: see Installation.
5. What else has to be considered?
Disconnect the product from power, before you…
clean or maintain the product.
do any works on the product or its components (electric expert).
227174/75/76/84 02/2008 © by SLV Elektronik GmbH
Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany
Technical Details are subject to change. Duplication prohibited !
1
3
3
2
1
4
5
LN
ENGLISH
Instruction Manual
for outdoor fitting
KERAS