Specification

76
Repair Parts and Maintenance Guide
The information contained in this document is subject to change without notice.
G2 Flushometer
Sloan introduced its Optima Plus
®
battery powered sensor flushometer
in 1992, revolutionizing the flushing of water closets and urinals. In both
new construction and retrofit applications, the use of the Optima Plus
has become the standard method for many facilities to improve restroom
hygiene and ensure handicap accessibility compliance.
In May, 2003 Sloan introduced the G2 Optima Plus.
The G2 Optima Plus builds on the success of the original product and
offers many technological advancements to further improve on performance
and reliability expected of sensor activated plumbing. In addition to a new
aesthetic design, the G2 Optima Plus features a new state-of-the-art
electronic and optical package and a unique solenoid operator that keeps
the moving components of the solenoid completely isolated from the water
supply. This ensures long life and low maintenance regardless of local
water condition.
The G2 Optima Plus replaces the original Optima Plus product, which was
phased out of production in mid-2003.
The Sloan G2 Optima Plus automatic battery powered flushometer relies
on an infrared sensor to detect a user and activate a flushing cycle. No
physical contact with the flushometer surface is necessary, assuring sanitary
protection. G2 Optima Plus flushometers are ADA compliant devices.
The flushometer is triggered by means of an active infrared sensor. The
Optima Plus sensor emits a continuous invisible light beam. When a user
enters the beam’s effective range, the beam is reflected into the Optima
Plus scanner window. The user is now detected. After the user moves out of
the effective range of the sensor, a signal is sent to the flushometer solenoid
and, after appropriate arming and/or flush delays, the flush cycle is initiated.
ITEM 10. FLEX TUBE DIAPHRAGM KIT
Regulator
Code No. Part No. Description Color *
3325090 EBV-1025-A Urinal-0.125 gpf/0.25 gpf GREEN
3325003 EBV-1023-A Urinal-0.5 gpf/1.9 Lpf
†‡
GREEN
3325000 EBV-1022-A Urinal-1.0 gpf/3.8 Lpf GREEN
3325000 EBV-1022-A Urinal-1.5 gpf/5.7 Lpf
BLACK
3325001 EBV-1020-A Urinal-3.5 gpf/13.2 Lpf
WHITE
3325031 EBV-1024-A Closet-1.28 gpf/4.8 Lpf GREEN
3325001 EBV-1020-A Closet-1.6 gpf/6.0 Lpf
GREEN
3325014 EBV-1021-A Closet-2.4 gpf/9.0 Lpf BLUE
3325001 EBV-1020-A Closet-3.5 gpf/13.2 Lpf WHITE
3325001 EBV-1020-A Closet-4.5 gpf/17.0 Lpf
§
WHITE
EBV-1020-A and EBV-1022-A are supplied with multiple regulators.
A 0.5 gpf (1.9 Lpf) urinal kit can be converted to a 1.0 gpf (3.8 Lpf) by cutting and removing the
smooth A-164 flow ring from the guide.
§ For a 4.5 gpf (17 Lpf) water closet flush use EBV-1020-A with the white regulator, and cut and remove the
A-164 flow ring from the guide.
* Color of regulator to be used with flex tube diaphragm to obtain the listed flush volume.
EBV-1025-A includes H-1015A Flow Control
COVER
BODY
FLUSH CONNECTION
(VACUUM BREAKER)
SPUD COUPLING
LOCKING RING
STOP COUPLING
CONTROL
STOP
SUPPLY FLANGE
TAILPIECE
OUTLET COUPLING
SPUD FLANGE
OVERRIDE BUTTON
O-RING
Code No. Part No. Description
5325056 EBV-83 O-ring – 6 per package
REGULATOR
(MUST BE
INSTALLED
PAST 0-RING)
REGULATOR
O-RING
(Code No. 5325056)
FLEX TUBE
DIAPHRAGM
REGULATORS
The flush volume of the flex tube diaphragm kit is controlled by the
regulator. Regulators are identified by color. Some flex tube diaphragm kits
are supplied with multiple regulators. The installer must make sure the
proper regulator is used when installing the flex tube diaphragm kit.
REGULATOR (SOLD 6 PER PACKAGE)
Regulator
Code No. Part No. Description Color
5325122 EBV-95 Urinal-0.25 gpf/1.0 Lpf GREEN
5325122 EBV-95 Urinal-0.5 gpf/1.9 Lpf GREEN
5325122 EBV-95 Urinal-1.0 gpf/3.8 Lpf GREEN
5325129 EBV-102-2 Urinal-1.5 gpf/5.7 Lpf BLACK
5325130 EBV-102-1 Urinal-3.5 gpf/13.2 Lpf WHITE
5325122 EBV-95 Closet-1.28 gpf/4.8 Lpf GREEN
5325122 EBV-95 Closet-1.6 gpf/6.0 Lpf GREEN
5325130 EBV-102-1 Closet-3.5 gpf/13.2 Lpf WHITE
5325128 EBV-101 Closet-2.4 gpf/9.0 Lpf BLUE
EBV-1020-A and EBV-1022-A are supplied with multiple flush volume regulators.
The installer must use the correct regulator when installing the kit.
ITEM 16A. SLIP JOINT GASKETS AND RINGS
Size Code No. Part No. Description
1-1/2” 5306058 F-3 Red Friction Ring
5322001 VBF-5 Black Slip Joint Gasket
0319086/5319086 S-30 Flexible Seat
0319079 S-21 Rigid Seat (rubber over brass)
1-1/2” x 1-1/4” 0396062 F-105 Slip Joint Gasket – Rigid
1-1/4” 5306057 F-3 Red Friction Ring
5322176 VBF-5 Black Slip Joint Gasket
0307052/5307052 G-21 Rigid Seat (rubber over brass)
1 5306056 F-3 Red Friction Ring
5306115 F-5 Black Slip Joint Gasket
3/4” 5306055 F-3 Red Friction Ring
5306113 F-5 Black Slip Joint Gasket