Spec Sheet
ROYAL® MANUAL FLUSHOMETER
ROYAL 611-1.6-7-3/4-LDIM-L3
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 3918921 • Downloaded 06/29/21 • 07/28/20 • View Latest Version
Page 1 of 2
CODE NUMBER
3918921
DESCRIPTION
1.6 gpf, Rough Brass Finish, Fixture Connection Rear Spud, Single
Flush, 7.75 L Dimension, 3" Metal Oscillating Push Button, Royal®
Concealed Manual Water Closet Flushometer.
DETAILS
Flush Volume: 1.6 gpf (6.0 Lpf)
Finish: Rough Brass (RB)
Valve: Diaphragm
Valve Body Material: Semi-red Brass
Fixture Type: Water Closet
Fixture Connection: Rear Spud
Rough-In Dimension: 24" (610mm)
Spud Coupling: 1 ½" (38mm)
Supply Pipe: 1" (25mm)
L Dimension: 7 ¾" (197mm) (7-3/4-LDIM)
Push Button: 3" Metal Oscillating (L3)
FEATURES
Royal® and Regal® Prison Flushometers feature all the
performance benefits of standard concealed, diaphragm model
Flushometers with added durability to withstand rough
environments
Various flush volumes available to match with existing fixtures and
meet water-efficiency goals
Choose from Flushometers intended for use with stainless-steel
water closet fixtures from Acorn®, Metcraft® and other
manufacturers
Diaphragm, handle packing, stop seat and vacuum breaker molded
from PERMEX® rubber compound for chloramine resistance
Vandal-proof, push-button operation designed with non-hold-open
feature to keep fixture from surpassing intended water
consumption
Adjustable tailpiece accommodates various installation heights
PERMEX synthetic rubber diaphragm with Dual Filtered Fixed
Bypass
Valve body, Cover, Tailpiece and Control Stop shall be in
compliance with ASTM Alloy Classification for Semi-Red Brass
Valve shall be in compliance to the applicable sections of ASSE
1037.
COMPLIANCES & CERTIFICATIONS
(cUPC Certified, BAA Compliant)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi- Red
Brass. Valve shall be in compliance with the applicable
sections of ASSE 1037 and ANSI/ASME 112.19.2.
VALVE OPERATING PRESSURE (FLOWING)
15 – 80 PSI (103 – 552 kPa). Specific fixtures may require greater
minimum flowing pressure - consult manufacturer
requirements.
DOWNLOADS
Concealed Flushometer Installation Instructions for Stainless
Steel Fixtures
Control Stop Repair and Maintenance Guide
Flush Connections Flanges Repair and Maintenance Guide
Tail Piece Repair and Maintenance Guide
Additional Downloads
NOTES
All information contained within this document subject to
change without notice.
Looking for other variations of the ROYAL 611 product? View
the general spec sheet with all options.
Find a compatible urinal for this flushometer.