Spec Sheet

Code NumberCode Number
3772672
DescriptionDescription
Exposed, Sensor Activated Sloan® Model Urinal Flushometer for ¾”
top spud urinals.
SpecificationsSpecifications
Quiet, Exposed, Diaphragm Type, Chrome Plated Urinal Flushometer
for either left or right hand supply with the following features:
Vacuum Breaker with Flush Connection
Sweat Solder Adapter with Cover Tube and Cast Wall Flange
¾” I.P.S. Screwdriver Bak-Chek® Angle Stop with Vandal Resistant
Stop Cap
Spud Coupling and Spud Flange for ¾” Top Spud
No External Volume Adjustment to Ensure Water Conservation
OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator
Light
Diaphragm, Stop Seat and Vacuum Breaker Molded from
PERMEX® Rubber Compound for Chloramine Resistance
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi-Red Brass.
Valve shall be in compliance with the applicable sections of ASSE
1037. Installation conforms to ADA requirements.
Accessories (specify separately)Accessories (specify separately)
Transformer (120 VAC/24 VAC 50 VA)
Transformer (240 VAC/24 VAC 50 VA)
Flushometer Electrical Box Positioning and Support Kit
VariationsVariations
DFB Dual Filtered Fixed Bypass Diaphragm (0.5 gpf ONLY) Code
No: 3782691
FixturesFixtures
Consult factory for matching Sloan brand fixture options.
Control CircuitControl Circuit
Solid State
8 Second Arming Delay
24 VAC Input
24 VAC Output
Solenoid OperatorSolenoid Operator
24 VAC, 50/60 Hz
TransformersTransformers
Sloan Part #EL-154 120 VAC, 50/60 Hz Primary 24 VAC, 50/60 Hz
Secondary Class II, UL Listed, 50 VA.
Sloan Part #EL-342 240 VAC, 50/60 Hz Primary 24 VAC, 50/60 Hz
Secondary Class II, UL Listed, 50 VA.
Accessories (Sold Separately)Accessories (Sold Separately)
See Accessories Section and OPTIMA Accessories Section of the
Sloan catalog for details on these and other OPTIMA Flushometer
variations.
Sensor RangeSensor Range
Nominal 12” - 32” (305 mm - 813 mm) Self-adaptive Window: ± 10”
(254 mm)
Automatic OperationAutomatic Operation
Sloan OPTIMA® equipped Flushometers provide the ultimate in
sanitary protection and automatic operation. There are no handles
to trip or buttons to push. The Flushometer operates by means of an
infrared sensor that adapts to its surrounding. Once the user enters
the sensor’s effective range and then steps away, the Flushometer
Solenoid initiates the flushing cycle to flush the fixture.
HygienicHygienic
User makes no physical contact with the Flushometer surface
except to initiate the Override Button when required. Helps control
the spread of infectious diseases.
EconomicalEconomical
Automatic operation provides water usage savings over other
flushing devices. Reduces maintenance and operation costs.
PracticalPractical
Solid state electronic circuitry assures years of dependable, trouble-
free operation. The operational components of the Flushometer are
identical to a handle operated Sloan® Flushometer.
Compliance & CertificationsCompliance & Certifications
This space for Architect/Engineer Approval
ROUGH-INROUGH-IN
Sloan® Model OPTIMA® Sensor
Activated Flushometers
186-1.0 ES-S
2017-09-02 Page 1 of 2
SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. 60131 60131
Ph: 1-800-9-VALVE-9 or 1-847-671-4300 ● Fax: 1-800-447-8329 or 1-847-671-4380 ● http://www.sloan.com

Summary of content (2 pages)