Spec Sheet

SLOAN® SENSOR FLUSHOMETER
SLOAN 186 ESS-0.125-DBP-TMO-HW
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 3772645 • Downloaded 06/10/21 • 07/28/20 • View Latest Version
Page 1 of 2
CODE NUMBER
3772645
DESCRIPTION
0.125 gpf, Dual-Filtered Bypass, Polished Chrome Finish, Fixture
Connection Top Spud, Single Flush, True Mechanical Override,
Hardwired, Sensor-Operated, Sloan® Exposed Sensor Hardwired
Urinal Flushometer.
DETAILS
Flush Volume: 0.125 gpf (0.5 Lpf)
Finish: Polished Chrome (CP)
Power Type: Hardwired (HW)
Valve: Diaphragm
Bypass: Dual-Filtered Bypass (DBP)
Valve Body Material: Semi-red Brass
Fixture Type: Urinal
Fixture Connection: Top Spud
Rough-In Dimension: 11 ½" (292mm)
Spud Coupling: ¾" (19mm)
Supply Pipe: ¾" (19mm)
Override: True Mechanical (TMO)
FEATURES
PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
Handle Packing, Main Seat, Stop Seat and Vacuum Breaker Molded
from PERMEX® Rubber Compound for Chloramine resistance
User friendly three (3) second Flush Delay
Sweat solder adapter with cover tube and cast wall flange with set
screw
OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
“Walk By” Delay of Eight (8) Seconds Prevents Unintentional
Flushes
Non-Hold-Open True Mechanical Override
Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass
and No External Volume Adjustment to Ensure Water Conservation
Courtesy FlushTM Non-Hold-Open True Mechanical Override
High Back Pressure Vacuum Breaker Flush Connection with One-
Piece Bottom Hex Coupling Nut, Spud Coupling and Flange for 3⁄4”
Top Spud
3⁄4” I.P.S. Screwdriver Bak-Chek® Angle Stop with Vandal Resistant
Stop Cap
VIDEOS
ESS Flushometer
COMPLIANCES & CERTIFICATIONS
(ADA Compliant, BAA Compliant, BREEAM Water Credit, cUPC
Certified, cUPC Green Certified, Green Globes Water Credit,
LEED V4 Water Efficiency Credit, Satisfies LEED Credits, UL
Certified, WaterSense Listed)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi- Red
Brass. Valve shall be in compliance with the applicable
sections of ASSE 1037 and ANSI/ASME 112.19.2.
ELECTRICAL SPECIFICATIONS
Arming Delay: 8 seconds
Control Circuit: Solid State/24 VAC Input/24 VAC Output
Self-Adaptive Window: ±8
Sensor Range: 15" – 30" (381 – 762mm)
Solenoid Operator: 24 VAC
Transformers:
0345154
0345999
VALVE OPERATING PRESSURE (FLOWING)
15 – 80 PSI (103 – 552 kPa). Specific fixtures may require greater
minimum flowing pressure - consult manufacturer
requirements.
DOWNLOADS
Sloan Exposed Installation Instructions
Sloan Exposed (Spanish) Installation Instructions
Sloan Concealed Installation Instructions
Sloan / Regal Optima ESS Installation Instructions
Control Stop Repair and Maintenance Guide
Flush Connections Flanges Repair and Maintenance Guide
Tail Piece Repair and Maintenance Guide

Summary of content (2 pages)