Spec Sheet
CROWN® SENSOR FLUSHOMETER
CROWN 152 ESS-1.6-HW
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 3520006 • Downloaded 06/29/21 • 07/28/20 • View Latest Version
Page 1 of 2
CODE NUMBER
3520006
DESCRIPTION
1.6 gpf, Rough Brass Finish, Fixture Connection Rear Spud, Single
Flush, Hardwired, Sensor-Operated, Crown® Concealed Sensor
Hardwired Water Closet Flushometer.
DETAILS
Flush Volume: 1.6 gpf (6.0 Lpf)
Finish: Rough Brass (RB)
Power Type: Hardwired (HW)
Valve: Piston
Valve Body Material: Semi-red Brass
Fixture Type: Water Closet
Fixture Connection: Rear Spud
Rough-In Dimension: 24" (610mm)
Spud Coupling: 1 ½" (38mm)
Supply Pipe: 1" (25mm)
FEATURES
PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
User friendly three (3) second Flush Delay
OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
Die Cast Sensor Plate with no visible Fasteners (for 2-gang
Electrical Box)
Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass
and No External Volume Adjustment to Ensure Water Conservation
Stop Seat and Vacuum Breaker molded from PERMEX® Rubber
Compound for Chloramine Resistance
High Back Pressure Vacuum Breaker Flush Connection and Spud
Coupling for 1 1/2” Concealed Back Spud
1” I.P.S. Wheel Handle Bak-Chek® Angle Stop
Courtesy Flush® Override Button
VIDEOS
ESS Flushometer
COMPLIANCES & CERTIFICATIONS
(ADA Compliant, cUPC Certified, BAA Compliant, UL Certified)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi- Red
Brass. Valve shall be in compliance with the applicable
sections of ASSE 1037 and ANSI/ASME 112.19.2.
ELECTRICAL SPECIFICATIONS
Arming Delay: 16 seconds
Control Circuit: Solid State/24 VAC Input/24 VAC Output
Flush Delay: 3s
Self-Adaptive Window: ±10
Sensor Range: 22" – 42" (559 – 1,067mm)
Solenoid Operator: 24 VAC
VALVE OPERATING PRESSURE (FLOWING)
15 – 80 PSI (103 – 552 kPa). Specific fixtures may require greater
minimum flowing pressure - consult manufacturer
requirements.
DOWNLOADS
Sloan Piston Type Exposed Installation Instructions
Control Stop Repair and Maintenance Guide
Flush Connections Flanges Repair and Maintenance Guide
Tail Piece Repair and Maintenance Guide
Crown/Crown II Repair and Maintenance Guide
Concealed Flushometers Repair and Maintenance Guide
Optima ESS Repair and Maintenance Guide