Spec Sheet
ROYAL® SENSOR FLUSHOMETER
ROYAL 197 ESS-0.5-11-12-3/4-LDIM-HW
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 3453232 • Downloaded 06/10/21 • 07/28/20 • View Latest Version
Page 1 of 2
CODE NUMBER
3453232
DESCRIPTION
0.5 gpf, Rough Brass Finish, Fixture Connection Top Spud, Single
Flush, 11-12.75 L Dimension, Hardwired, Sensor-Operated, Royal®
Concealed Sensor Hardwired Urinal Flushometer.
DETAILS
Flush Volume: 0.5 gpf (1.9 Lpf)
Finish: Rough Brass (RB)
Power Type: Hardwired (HW)
Valve: Diaphragm
Valve Body Material: Semi-red Brass
Fixture Type: Urinal
Fixture Connection: Top Spud
Rough-In Dimension: 13 ½" (343mm)
Spud Coupling: ¾" (19mm)
Supply Pipe: ¾" (19mm)
L Dimension: 11" – 12 ¾" (279 – 324mm) (11-12-3/4-LDIM)
FEATURES
Quiet, Concealed, Diaphragm Type, Rough Brass Urinal
PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass
and No External Volume Adjustment to Ensure Water Conservation
Courtesy FlushTM Non-Hold-Open True Mechanical Override
OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
Stop Seat and Vacuum Breaker molded from PERMEX® Rubber
Compound for Chloramine Resistance
High Back Pressure Vacuum Breaker Flush Connection, Spud
Coupling and Flanges for 3⁄4” Exposed Top Spud
3/4” I.P.S. Wheel Handle Bak-Chek® Angle Stop
VIDEOS
ESS Flushometer
COMPLIANCES & CERTIFICATIONS
(ADA Compliant, BAA Compliant, BREEAM Water Credit, cUPC
Certified, cUPC Green Certified, Green Globes Water Credit,
LEED V4 Water Efficiency Credit, Satisfies LEED Credits, UL
Certified, WaterSense Listed)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi- Red
Brass. Valve shall be in compliance with the applicable
sections of ASSE 1037 and ANSI/ASME 112.19.2.
ELECTRICAL SPECIFICATIONS
Arming Delay: 8 seconds
Control Circuit: Solid State/24 VAC Input/24 VAC Output
Self-Adaptive Window: ±8
Sensor Range: 15" – 30" (381 – 762mm)
Solenoid Operator: 24 VAC
Transformers:
0345154
0345999
VALVE OPERATING PRESSURE (FLOWING)
15 – 80 PSI (103 – 552 kPa). Specific fixtures may require greater
minimum flowing pressure - consult manufacturer
requirements.