Spec Sheet

ROYAL® SENSOR FLUSHOMETER
ROYAL 190 ESS-3.5-OR-2-10-3/4-LDIM-HW
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 3453003 • Downloaded 06/10/21 • 07/28/20 • View Latest Version
Page 1 of 2
CODE NUMBER
3453003
DESCRIPTION
3.5 gpf, Rough Brass Finish, Fixture Connection Rear Spud, Single
Flush, 2-10.75 L Dimension, Electrical Override, Hardwired, Sensor-
Operated, Standard (not included, order separately) Wall Box, Royal®
Concealed Sensor Hardwired Urinal Flushometer.
DETAILS
Flush Volume: 3.5 gpf (13.2 Lpf)
Finish: Rough Brass (RB)
Power Type: Hardwired (HW)
Valve: Diaphragm
Valve Body Material: Semi-red Brass
Fixture Type: Urinal
Fixture Connection: Rear Spud
Rough-In Dimension: 14 ½" (368mm)
Spud Coupling: 1 ¼" (32mm)
Supply Pipe: 1" (25mm)
L Dimension: 2" – 10 ¾" (51 – 273mm) (2-10-3/4-LDIM)
Override: Electrical (OR)
Wall Box: Standard (not included, order separately) ()
FEATURES
PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
1” I.P.S. Wheel Handle Bak-Chek® Angle Stop
Diaphragm, Stop Seat and Vacuum Breaker to be molded from
PERMEX® rubber compound for Chloramine resistance
13 1⁄2” x 13 1⁄2” Wall Box with Stainless Steel Access Panel and
Vandal Resistant Screws
Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass
and No External Volume Adjustment to Ensure Water Conservation
OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
Quiet, Concealed, Diaphragm Type, Rough Brass Urinal
High Back Pressure Vacuum Breaker Flush Connection and Spud
Coupling for 11⁄4” Concealed Back Spud
13” x 17” EASY ACCESS® Wall Box with Stainless Steel Access
Panel and Vandal Resistant Screws
VIDEOS
ESS Flushometer
COMPLIANCES & CERTIFICATIONS
(UL Certified, ADA Compliant, UPC Certified, BAA Compliant)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi- Red
Brass. Valve shall be in compliance with the applicable
sections of ASSE 1037 and ANSI/ASME 112.19.2.
ELECTRICAL SPECIFICATIONS
Arming Delay: 8 seconds
Control Circuit: Solid State/24 VAC Input/24 VAC Output
Self-Adaptive Window: ±8
Sensor Range: 15" – 30" (381 – 762mm)
Solenoid Operator: 24 VAC
Transformers:
0345154
0345999
VALVE OPERATING PRESSURE (FLOWING)
15 – 80 PSI (103 – 552 kPa). Specific fixtures may require greater
minimum flowing pressure - consult manufacturer
requirements.
DOWNLOADS
Royal ESS Concealed with Wall Box Installation Instructions
Control Stop Repair and Maintenance Guide
Flush Connections Flanges Repair and Maintenance Guide
Tail Piece Repair and Maintenance Guide
Optima ESS Repair and Maintenance Guide
Additional Downloads
NOTES
All information contained within this document subject to
change without notice.
Looking for other variations of the ROYAL 190 ESS product?
View the general spec sheet with all options.

Summary of content (2 pages)