Specification Sheet
►► Code NumberCode Number
3070024
►► DescriptionDescription
Exposed, Battery Powered, Side Mount Sensor Operated Water
Closet Flushometer for floor mounted or wall hung top spud bowls.
►► Flush CycleFlush Cycle
1.28 gpf/4.8 Lpf
►► SpecificationsSpecifications
Quiet, Exposed, Piston Type, Chrome Plated Closet Flushometer with
the following features:
● ● ADA Compliant OPTIMA® Battery Powered Infrared Sensor for
automatic “No Hands” operation
● ● Fixed Volume Piston with Filtered O-ring Bypass
● ● Chrome Plated Infrared Sensor Housing
● ● Angled Sensor Window
● ● Manual Override Flush Button
● ● Four (4) Size C Batteries included
● ● “Low Battery” Flashing LED with Optional Audio Tone
● ● “User in View” Flashing LED
● ● Optional 24-Hour Sentinel Flush
● ● Infrared Sensor Range Adjustment Screw and Reset Button
● ● EBV-157 Handle Adapter Kit
● ● Vacuum Breaker Flush Connection
● ● Spud Coupling, Wall and Spud Flanges for 1½" Top Spud
● ● No External Volume Adjustment to Ensure Water Conservation
● ● High Copper, Low Zinc Brass Castings for Dezincification
Resistance
● ● 1" I.P.S. Screwdriver Bak-Chek® Angle Stop with Vandal Resistant
Stop Cap
● ● Diaphragm, Stop Seat and Vacuum Breaker to be molded from
PERMEX® rubber compound for Chloramine resistance
►► VariationsVariations
☐ DFB Dual Filtered Fixed Bypass
☐ XL Sweat Solder Adapter and Cast Set Screw Wall Flange
☐ YG Extended Bumper on Angle Stop (for seat with cover)
☐ YK - Solid Ring Pipe Support
☐ XYV - Valve Less Vacuum Breaker
☐ NOTE: Bak-Chek® Angle Stop available with 1” Whitworth Thread
(please specify).
☐ YO - Angle Stop Bumper
☐ YJ - Split Ring Pipe Support
☐ U - 1 1/4" Vacuum Breaker
►► Automatic OperationAutomatic Operation
Sloan OPTIMA SMO equipped Flushometers provide the ultimate in
sanitary protection and automatic operation. There is no need for
AC hookups or wall alterations. The Flushometer operates by means
of a battery powered infrared sensor. Once the user enters the
sensor’s effective range and then steps away, the Side Mount Unit
initiates the flushing cycle to flush the fixture.
►► HygienicHygienic
User makes no physical contact with the Flushometer surface
except to initiate the Override Button when required. Helps control
the spread of infectious diseases.
►► EconomicalEconomical
Automatic operation provides water usage savings over other
flushing devices. Reduces maintenance and operation costs.
►► Compliance & CertificationsCompliance & Certifications
This space for Architect/Engineer Approval
►► OPERATIONOPERATION
GEM2® OPTIMA® Flushometers
111-1.28 SMO
2017-12-12 Page 1 of 2
SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. SLOAN 10500 SEYMOUR AVE. ● FRANKLIN PARK, ● IL. 60131 60131
Ph: 1-800-9-VALVE-9 or 1-847-671-4300 ● Fax: 1-800-447-8329 or 1-847-671-4380 ● http://www.sloan.com