Spec Sheet

WATER CLOSET & FLUSHOMETER COMBO
WETS-2000.1302
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 20001302 • Downloaded 07/02/21 • 08/27/20 • View Latest Version
Page 1 of 2
CODE NUMBER
20001302
DESCRIPTION
ST-2009 Water Closet and ROYAL 111 SMOOTH Flushometer.
COMPONENTS
Flushometer: Code 3910059
Water Closet: Code 2102009
DETAILS
Flush Volume: 1.28 gpf (4.8 Lpf)
Nominal Dimensions: 26 ¾" × 14" × 15" (679 × 356 × 381mm)
FLUSHOMETER FEATURES
PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
Non-Hold-Open Handle, Fixed Metering Bypass and No External
Volume Adjustment to Ensure Water Conservation
Spud Coupling and Spud Flange for 11⁄2” Top Spud
Sweat Solder Adapter with Cover Tube and Cast Wall Flange
High back pressure Vacuum Breaker with flush connection
1” I.P.S. Screwdriver Bak-Chek® Angle Stop with Free Spinning
Vandal Resistant Stop Cap
Stop Seat and Vacuum Breaker molded from PERMEX® Rubber
Compound for Chloramine Resistance
Optima SMOOTHTM Unit
“User in View” Flashing LED
Sensor with Automatic Range Adjustment
Mechanical Manual Override Flush Handle
ADA Compliant Metal Oscillating Non-Hold-Open Handle
FIXTURE FEATURES
White Vitreous China
Elongated bowl
Floor mounted, floor outlet
Siphon jet flushing action achieves 1000g Map score when used
with any Sloan flushometer
Water spot area: 10⅛" x 9⅜" (26 cm x 24 cm)
1½" I.P.S. top spud inlet
2⅛" fully glazed trapway
Closet bolts and caps included
Toilet seat not included
Static load rating of 1000 lbs. (See Notes)
WaterSense compliant when used with a WaterSense compliant
flushometer
COMPLIANCES & CERTIFICATIONS
(BREEAM Water Credit, Green Globes Water Credit, LEED V4
Water Efficiency Credit, Satisfies LEED Credits, WaterSense
Listed, BAA Compliant)
DOWNLOADS
SS/ST/SU/WETS/WEUS Fixtures Repair and Maintenance
Guide
Additional Downloads
NOTES
All information contained within this document subject to
change without notice.
Static load tested according to the procedure outlined in
Section 6.7 of ASME A112.19.2. Not recommended for bariatric
use.