Specification Sheet
DESCRIPTION
Complete HEU system with Exposed, Hardwired, Dual Flush,
Sensor Activated Sloan ECOS
®
urinal Flushometer with Smart
Sense Technology™ and vitreous china urinal.
Flush Cycle
Model WEUS 1000.1411-0.125 ECOS
®
(0.125 gpf/0.5 Lpf)
Code: 10001411
This space for Architect/Engineer approval
Job Name Date
Model Specified Quantity
Variations Specified
Customer/Wholesaler
Contractor
Architect
SPECIFICATIONS
(CONTINUED)
Urinal
• Wall hung vitreous china
• Washdown flushing action
• Vandal resistant strainer assembly included
• 3/4” I.P.S. top spud inlet
• 2” NPT outlet flange
• All mounting hardware included
• Integral flushing rim
• 100 % factory flush tested
• Compliant to the applicable sections
of ASME A112.19.2/CSA B45.1
• Carrier not included
• Compliant with Buy American Act when purchased
as a combination
FEATURES
ADA Compliant
Automatic
Sloan ECOS
®
Hardwire Electronic Flushometers are
activated via multi-lobular infrared sensor. Sloan ECOS
®
Electronic Urinal Flushometers are available without an
override button to eliminate unnecessary casual
activation. By detecting user presence and duration, the
Sloan ECOS
®
Hardwire Smart Sense Technology™ will
determine the proper flush volume for unequalled water
efficiency.
Functional & Hygienic
Touchless, sensor operation eliminates the need for
user contact to help control the spread of infectious
diseases. The Sloan ECOS
®
Hardwire Flushometer is
also provided with an Override Button to allow a
"courtesy flush" for individual user comfort.
Smart Sense Technology
The Sloan ECOS
®
Hardwire Flushometer is equipped
with Smart Sense Technology™ which applies extended
range and logic techniques to significantly reduce water
usage in high use urinal applications;such as when a
continuous line of people, also known as a queue.
forms. In fact during continuous queue, regardless the
number of users, the maximum amount of water used
is only 2.0 gallons. Please contact Sloan for specific
Details.
Warranty
3 year (limited)
The information contained in this document is subject to change without notice.
Sloan Valve Company
10500 Seymour Avenue
Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9 (982-5839)
or 1-847-671-4300
Fax: 1-800-447-8329 or 1-847-671-4380
www.sloanvalve.com
copyright © 2014 Sloan Valve company
WEUS-1000.1411 03-14
SPECIFICATIONS
Quiet, exposed, chrome plated urinal Flushometer for
either left or right hand supply with the following
features:
Flushometer
• ADA Compliant Sloan ECOS
®
Hardwired Infrared
Sensor for automatic “No Hands” operation
• Reduces water usage up to 80% over standard
sensor urinal
• Engineered Metal Cover with replaceable Lens Window
• Courtesy Flush
®
Override Button
• Line Powered with 6 VAC Step Down Transformer
• Infrared Sensor Range Adjustment Screw
• Initial Set-up Range Indicator Light (first 10 minutes)
• 3/4” I.P.S. Screwdriver Bak-Chek
®
Angle Stop
• Free spinning, Vandal Resistant Stop Cap
• High Efficiency cartridge assembly
• Flush Accuracy Controlled by CID Technology
• Latching Solenoid Operator
• User friendly three (3) second Flush Delay
• Synthetic rubber seals for chloramine resistance
• High Back Pressure Vacuum Breaker Flush
Connection with One-piece Bottom Hex Coupling Nut
• Spud Coupling and Flange for 3/4” Top Spud
• Sweat Solder Adapter w/Cover Tube and Cast
Wall Flange w/Set Screw
• Infrared Sensor with Multiple-focused, Lobular
Sensing Fields for high and low target detection
• High copper, low zinc brass castings for
dezincification resistance
• Patented D598,974
• Fixed Metering Bypass and no external volume
adjustment to ensure water conservation
• Stop Seat and Vacuum Breaker to be molded from
PERMEX
®
rubber compound for chloramine
resistance
• Valve Body, Cover, Tailpiece and Control Stop shall
be in conformance with ASTM Alloy Classification
for Semi-Red Brass. Valve shall be in compliance
to the applicable sections of ASSE 1037/ ASME
A112.19.2/CSA B45.1
NOTE
: Plumbing System Requirements
√ Minimum
Flowing
Pressure: 25 PSI
√ Minimum Fixture Static Pressure: 80 PSI
Meets the American Disabilities Guidelines and ANSI
A117.1 requirements when installed according to
these requirements.
Model
WEUS-1000.1411-0.125 ECOS
®
Hardwire
OPTIMA
®
Systems Hardwire HEU Flushometer and HEU Urinal
B
u
y
A
m
e
r
i
c
a
n
A
c
t
•
•
C
o
m
p
l
i
a
n
t
B
u
y
A
m
e
r
i
c
a
n
A
c
t
•
•
C
o
m
p
l
i
a
n
t
Efficiency Series