User Manual
13 / 17
Copyright (c) 2009-2017 RoboPeak Team
Copyright (c) 2013-2017 Shanghai Slamtec Co., Ltd.
Output
Figure 3-5 RPLIDAR Power Adapter Output Specification
Ripple wave and noise: When testing the ripple and noise, choose20Mhz
wideband when setting the oscilloscope, and the output end should have a 0.1uF
ceramic capacitor and a 10uF electrolytic capacitor connected in parallel. (the
input should be in 100Vac-240Vac).
Line/load regulation
Figure 3-6 RPLIDAR Power Adapter Line/Load Regulation
Turn-on delay
3s when the input is 100Vac and at maximum load.
2s when the input is 240Vac and at maximum load.
Holdup time
At least 30ms when shut the input is between 240Vac/50Hz and at maximum load.
Rise time
40ms when the input is between 100Vac-240 Vac and at maximum load.
Output overshoot/undershoot
7% is a maximum when powering on or off.
Output load transient response
Output
Loading
condition
Peak
load
Voltage
range
Ripple wave and
noise
Comments
5.0V
0.0A min
2.0A max
/
4.75V-
5.25V
≤100mV
Output
Loading condition
Load regulation
Line regulation
Comments
5.0V
0.0A min 2.0A max
±1%
±3%