Data Sheet
10 / 16
Copyright (c) 2009-2013 RoboPeak Team
Copyright (c) 2013-2016 Shanghai Slamtec Co., Ltd.
Power Supply and Consumption
Ranging scanner system and motor system are powered separately in RPLIDAR
A1. External system should provide power supply for them separately in order to
ensure data accuracy. Below chart showed a recommended power mode. More
specification is provided in the following table.
Figure 2-7 RPLIDAR A1 Power Recommended Power Mode
Figure 2-8 RPLIDAR A1 Power Supply Specification
MISC
o For Model A2M3/A2M4 Only
Item
Unit
Min
Typical
Max
Comments
Scanner system
voltage
Volt (V)
4.9
5
5.5
If the voltage exceeds the
max value, it may damage
the core.
Scanner system
voltage ripple
Millivolt(mV)
20
50
High ripple may cause the
core working failure.
Scanner system start
current
Milliampere
(mA)
TBD
500
600
Underpower may cause
the startup failure.
Scanner system
current
Milliampere
(mA)
TBD
80
100
Sleep mode, 5V input
TBD
300
350
Work mode, 5V input
Motor system voltage
Volt (V)
5
5
10
Adjust voltage according
to speed
Motor system current
Milliampere
(mA)
TBD
100
TBD
5V input
Scanner
System
Motor System
RPLIDAR
4.9V-5.5V DC, low ripple <1%
5V-10V DC, high current