Service Manual Instruction Manual

Electrical System
9-36
6036, 6042, 8042, 10042, 10054
1117 627 2 None Power Supply
Power Lost With Ignition OnData Erratic, Intermittent,
or Incorrect
343 629 12 Amber Controller #1
Engine Control Module Warning internal hardware failure - Bad
Intelligent Device or Component
2311 633 31 Amber
Fuel Control
Valve #1
Fueling Actuator #1 Circuit Error—Condition Exists
285 639 9 Amber
SAE J1939
Datalink
SAE J1939 Multiplexing PGN Timeout Error—Abnormal
Update Rate
286 639 13 Amber
SAE J1939
Datalink
SAE J1939 Multiplexing Configuration Error—Out of
Calibration
599 640 14 Red
Engine
External
Protection
Input
Auxiliary Commanded Dual Output Shutdown—
Special Instructions
237 644 2 Amber
External
Speed Input
External Speed Input (Multiple Unit Synchronization)—Data
Erratic, Intermittent, or Incorrect
245 647 4 Amber
Fan Clutch
Output Device
Driver
Fan Control Circuit—Voltage Below Normal, or Shorted to Low
Source
2377 647 3 Amber
Fan Clutch
Output Device
Driver
Fan Control Circuit—Voltage Above Normal, or Shorted to
High Source
322 651 5 Amber
Injector
Cylinder #01
Injector Solenoid Cylinder #1 Circuit – Current Below Normal,
or Open Circuit
331 652 5 Amber
Injector
Cylinder #02
Injector Solenoid Cylinder #2 Circuit – Current Below Normal,
or Open Circuit
324 653 5 Amber
Injector
Cylinder #03
Injector Solenoid Cylinder #3 Circuit – Current Below Normal,
or Open Circuit
332 654 5 Amber
Injector
Cylinder #04
Injector Solenoid Cylinder #4 Circuit – Current Below Normal,
or Open Circuit
584 677 3 Amber
Starter
Solenoid
Lockout Relay
Driver Circuit
Starter Relay Driver Circuit—Voltage Above Normal, or
Shorted to High Source
527 702 3 Amber
Circuit—
Voltage
Auxiliary Input/Output 2 CircuitVoltage Above Normal, or
Shorted to High Source
529 703 3 Amber
Circuit—
Voltage
Auxiliary Input/Output 3 CircuitVoltage Above Normal, or
Shorted to High Source
Fault
Code
SPN
Code
FMI
Code
LAMP
Area
Description
Diagnostic Description