Owner's Manual

Rev. 2/1/06 Page 4 of 8
WIRING ELECTRONIC SPARK IGNITIONS
Most electronic systems operate on a 110 VAC/24VAC power transformer used to power
the system electronic ignition module and electronic gas valve, which can be controlled by
the 1410-A remote receiver as, illustrated.
NOTE: THE 110-120 VAC/ 24VAC, transformer may be purchased from your appliance
dealer, or an electronic parts distributor.
The remote control receiver can be connected, in series, to a 24VAC transformer to the
TR (transformer) terminal on the ELECTRONIC MODULE. Connect the hot wire from the
24VAC transformer to either of the wires on the remote receiver. Connect the other wire
from the receiver to the TH (thermostat) terminal on the ELECTRONIC MODULE.
SYSTEM CHECK
MILLIVOLT VALVES
Light your gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is on; it must be in
operation for the main gas valve to operate.
Slide the 3-position button on the remote receiver to the ON position. The main gas flame (i.e., the fire) should ignite.
Slide the button to OFF. The flame should extinguish (the pilot flame will remain on).
Slide the button to REMOTE (the center position) then press the ON button on the transmitter to change the system to ON. The
main gas flame should ignite.
ELECTRONIC IGNITION SYSTEMS
Slide the 3-position button on the remote receiver to the ON position. The spark electrode should begin sparking to ignite the pilot
(the pilot may ignite after only one spark). After the pilot flame is lit, the main gas valve should open and the main gas flame
should ignite.
Slide the button to OFF. The main gas flame and pilot flame should BOTH extinguish.
Slide the button to REMOTE (the center position), and then press the ON button on the transmitter to change the system to ON.
The spark electrode should begin sparking to ignite the pilot. After the pilot is lit, the main gas valve should open and the main gas
flame should ignite.
GENERAL INFORMATION
CP (CHILDPROOF) FEATURE
This SKYTECH remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT” operation of the
appliance, from the TRANSMITTER.
SETTING “LOCK-OUT” – (CP)
To activate the “LOCK-OUT” feature, press and hold the ON
button and the TIMER button at the same time for 5 seconds. The
letters CP will appear in the TEMP frame on the LCD screen.
To disengage the “LOCK-OUT”, press and hold the ON
button and the TIMER button at the same time for 5 seconds and the
letters CP will disappear from the LCD screen and the transmitter will return to its normal operating condition.
To verify that transmitter is in the CP lock-out mode press any key and the LCD screen will show “CP”
1 2 3 4 5 6
110/120VAC
input
REMOTE RECEIVER
ELECTRONIC MODULE
TR
TH
neutral wire
24VAC
hot wire
110/24VAC
Transformer