Installation Guide
REV 12/22/07 Page 5 of 9
WIRING INSTRUCTIONS
A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote should
install the remote control system. Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas
appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES
The remote receiver is to be connected to the millivolt valve.
Connect one of the (2) 18 gauge wires from the 5310 receiver to the TH terminal and the other to the
THTP terminal on the terminal block on the millivolt gas valve.
Operation of the remote receiver is similar to that of a thermostat in that both turn the gas valve on
and off based on input signals. A thermostat’s input signals are different temperatures. The remote
receiver’s input signals come from the transmitter.
WIRING ELECTRONIC SPARK IGNITIONS
Most electronic systems operate on a 110 VAC/24VAC power transformer used to power the system
electronic ignition module and electronic gas valve, which can be controlled by the 5310 remote
receiver as, illustrated.
NOTE: THE 110-120 VAC/ 24VAC, transformer may be purchased from your appliance dealer, or an
electronic parts distributor.
The remote control receiver can be connected, in series, to a 24VAC transformer to the TR
(transformer) terminal on the ELECTRONIC MODULE. Connect the hot wire from the 24VAC
transformer to either of the wires on the remote receiver. Connect the other wire from the receiver to
the TH (thermostat) terminal on the ELECTRONIC MODULE.
SYSTEM CHECK
MILLIVOLT VALVES
Light your gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is on; it must be in
operation for the main gas valve to operate.
• Slide the 3-position button on the remote receiver to the ON position. The main gas flame (i.e., the fire) should ignite.
• Slide the button to OFF. The flame should extinguish (the pilot flame will remain on).
• Slide the button to REMOTE (the center position) then press the MODE/SET button on the transmitter to change the system to ON. The
main gas flame should ignite.
1 2 3 4 5 6
REMOTE RECEIVER
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP
TP
TH
THERMOPILE/
PILOT LIGHT
110/120VAC
input
1 2 3 4 5 6
110/120VAC
input
REMOTE RECEIVER
ELECTRONIC MODULE
TR
TH
neutral wire
24VAC
hot wire
110/24VAC
Transformer