Installation Guide
REV.3/19-05 Page 7 of 16
countdown times are 15 min., 30 min, 45 min, 1 hr, 1 hr 30 min, 2
hr, 2 hr 30 min, and each additional half hour up to nine hours.
3. To set the TIMER press the SET
button on the transmitter. If the
system is ON, it will remain on until the “timer time” has expired. If
the system is in the THERMO mode, it will turn ON and OFF as the
room temperature requires until the “timer time” has expired.
4. To cancel the TIMER operation, press the TIMER/TIME
button for
more than 2 seconds.
OPERATIONAL NOTE:
When the TIMER is used in the THERMO mode, the THERMO operation will discontinue only when the
“countdown time” has expired.
OPERATING A FAN
- (Operates only in ON/THERMO/PROGRAM
MODES)
This remote control system has the capability of controlling the ON/OFF
operation of a 110 VAC fan or blower system that may
be included with
your gas appliance. It only operates the ON/OFF function for the
fan/blower and cannot adjust a variable speed controller. When
properly connected to the remote receiver, the fan will only go ON or
OFF by remote. You will still be able to vary the speed of the fan/blower
at the appliance,
but not remotely with the transmitter.
1. To turn the fan ON, press the Fan button on the transmitter. When
the fan is operating, the fan blade will display. Press the FAN
button to turn fan OFF. When the fan is off, OFF will display on the
LCD screen below the word FAN.
2. When the transmitter is in the THERMO or PROGRAM modes and
the FAN button is pressed to ON, the FAN will operate ON and
OFF as the cycling of the THERMO or PROGRAM occurs. IF the
FAN is in the OFF position, the fan will not operate until activated
by the FAN
button.
ADJUSTING THE FLAME HEIGHT
1. HI/LO SOLENOID
– Allows the user to change the flame height from LO to HI with a single press of the FLAME button. The word
HI and a second flame icon appears on the LCD screen when HI flame is operated.
OPERATING THE HI/LO SOLENOID
To operate the HI/LO control, from the transmitter, ON/THERMO ON or
PROGRAM ON must be displayed on the LCD screen. NOTE
User
must have FLAME CONTROLLER set to HI/LO. Review the procedure
SETTING THE FLAME CONTROLLER under INITIAL SET-UP
PROGRAMMING OF TRANSMITTER in earlier section.
1. Press the FLAME
button on the transmitter to change flame height
from LO to HI. You will note the word HI and a 2
nd
FLAME icon will
appear on the LCD screen. Press again to change from HI to LO.
The HI/LO flame controller is powered by a 24 VDC transformer. The orange wires from the FLAME terminals on the receiver are
attached to the terminals on the valve’s FLAME CONTROLLER.
NOTE:
How much the flame height changes, visually, depends on the BTU rating of the appliance. For example, the flame of a
30,000 BTU rated appliance will probably appear to change less than that of a 50,000 BTU rated appliance. This is a normal operating
condition.
NOTE:
During the first 5 seconds of operation, the flame height will operate at the highest setting to provide the most efficient ignition
for the appliance. It will then adjust to the previous setting.
TEMP
SET
WE
THERMO
ON
FLAME
FAN
OFF
HI
HI
1
UP
DOWN
MODE
TIMER
TIME
SET
PROG
AHEAD
BACK
FAN
FLAME
TEMP
SET
MO
PROGRAM
ON
FLAME
FAN
1
DAY
UP
DOWN
MODE
TIMER
TIME
SET
PROG
AHEAD
BACK
FAN
FLAME