Installation Guide
REV.3/19-05 Page 10 of 16
WIRING ELECTRONIC SPARK IGNITION
The remote receiver can be connected to a 24 VAC transformer that
operates an electronic ignition module, using the same VALVE
terminals on the remote receiver to complete the 24 VAC circuit to the
electronic ignition module.
Connect the neutral wire from the 24 VAC transformer to the TR
(transformer) terminal on the ELECTRONIC IGNITION MODULE.
Connect the hot wire from the 24 VAC transformer to either VALVE
terminal on the remote receiver. Connect another same-gauge wire
(not included) between the other VALVE terminal on the remote receiver
to the TH (thermostat) terminal on the ELECTRONIC IGNITION
MODULE.
INSTALLATION: 24 Volt DC HI/LOW SOLENOID
Notice: Please leave these instructions for the consumer and retain for
future reference.
Preparing the RS7000 valve to install the HI/LOW solenoid
5. Remove the phillips screw at the center of the HI/LOW manual control knob that holds the
HI/LOW manual control knob on the valve regulator.
6. Remove the manual control knob from the regulator shaft.
7. After removing the screw and manual control knob from the valve regulator you will need
to use a 7/16” wrench to remove the regulator shaft from the regulator. (Retain all parts to
reinstall at a later date, (If removal of the solenoid is required)
Installing and connecting the HI/LOW solenoid
.
8. After removing the solenoid from the plastic bag, You will need check the rating plate of
the gas appliance to determine if the valve that the solenoid is being installed on is
Natural or Propane Gas. You will find the Blue (Natural Gas) plunger installed in the
solenoid with a small piece of tape holding it in place for shipping. The Red (Propane
Gas) plunger is taped to the side of the solenoid. (Use caution: these plungers are
very small. After selecting the correct plunger (Red or Blue) insert the plunger into
the small hole on the threaded end on the solenoid. (Use caution while handling
solenoid that plunger does not fall out and get lost)
9. Thread (Screw) the solenoid with the selected (Red or Blue) plunger into the regulator
where the regulator shaft was removed from. (Use caution when threading the
solenoid into the regulator not to cross thread due to the fact that the regulator
is aluminum) Thread (Screw) the solenoid all the way in until the solenoid reaches the
bottom (Finger tight). Do not over tighten solenoid)
10. Hold the solenoid and tighten the jam nut down to hold the solenoid in place.
11. After solenoid is mounted on the valve.
12. Refer to the WIRING FLAME CONTROLLER section of this Sky 3324R
remote control installation instructions.
After wire connections have been completed, check the operation of the remote ON/OFF and
flame HI/LOW.
Caution: After any work is preformed on a control valve, always check for gas leaks
with soapy water.
1 2 3 4 5 6
to 24VAC
input
REMOTE RECEIVER
ELECTRONIC MODULE
TR
TH
neutral wire
24VAC
hot wire
110/24VAC
Transformer