User's Manual
REV 3/3/04
Page 4 of 5
GENERAL INFORMATION
WALL MOUNT THERMOSTAT OPERATION
FUNCTIONS
1. ROOM TEMP – Current room temperature.
2. F – Degrees Fahrenheit (C Indicates degrees Celsius)
3. FLAME ICON – Indicates APPLIANCE IS ON.
4. SET- Indicates transmitter is in thermostat mode.
5. DASHES – Indicate thermostat mode is being disabled. When
transmitter is not in the thermostat mode. The word (SET) will not appear.
1. This TS/R-2 Wall/transmitter has ON, OFF, and SET functions that are activated by pressing the
buttons on the face of the transmitter.
2. Upon initial use, there may be a delay of five seconds before the remote receiver will respond to the
transmitter. This is part of the system’s design. If the LCD will not come on, check the 3V-button cell
battery.
SETTING MANUAL OPERATION
1. When the ON button on the wall/transmitter is pressed a flame icon on the LCD screen wil appear
when the appliance is ON.
2. When the appliance is OFF the flame icon will not appear.
SETTING THREMOSTAT OPERATION
1. If the transmitter is in the thermostat mode the word (SET) will appear on the LCD screen.
2. When the SET button is pressed the temperature digits will begin to flash.
3. While the temperature digits are flashing use the ON button to increase the set temperature or
use the OFF button to decrease the set temperature to your desired temperature.
4. When the desired temperature setting is reached press the SET button, again and the word SET
will appear on the LCD screen and now the transmitter will automatically send an ON or OFF
signal to the receiver.
5. To disengage the thermostat mode push and hold the SET button until (2) dashes appear on the
LCD screen. When you release the SET button this will disengage the thermostat mode and the
word SET will disappear from the LCD screen.
SETTING
0
F /
0
C SCALE
The factory setting for temperature is degrees Fahrenheit (
0
F ) . To change this setting to Centigrade (
0
C ), you must press and hold both the
ON and OFF buttons on the transmitter at the same time until the LCD displays the change. If you want to convert back, repeat the above
procedure.
BATTERY LIFE
Life expectancy of alkaline batteries in the SKYTECH TS/R-2 should be at least 12 months. Replace all batteries annually. When the wall
thermostat no longer operates the receiver. Or the remote receiver does not function at all; the batteries should be checked. It is important that
the remote receiver batteries are fully charged, providing a combined output voltage of at least 5.3 volts. The length of the wire between the
remote receiver and the gas valve directly affects the operating performance of the remote system. The longer the wire, the more battery
power is required to deliver signals between the remote receiver and the gas valve. The wall thermostat should operate with as little as 4.0
volts battery power, Measured at the (2) 3 volt button cell batteries.