User's Manual

SWING Temperature: This model does not allow for SWING temperature adjustment.
This model utilizes thermostatic flame modulation that will modulation the main flame
based on the difference between room temperature and set temperature (see example
below).
o Important - factory SWING TEMPERATURE setting is 2 degrees. The
thermostatic flame modulation feature will not allow this SWING to be changed.
EXAMPLE:
Set Temperature Room Temp. Flame Level
74F OFF
73F Level 1
Set Temperature (72) 72F Level 2
71F (or less) Level 3
Pilot Method: Continuous/Standing Pilot only (Intermittent Pilot Ignition
(IPI)/Spark-to-Pilot not allowed).
o Pilot flame will remain ON when Main Flame Cycles ON and OFF.
Manual Flame Adjustment while in THERMOSTAT mode: If Flame-A is manually
adjusted while in thermostat mode, it will override the automatic flame setting until the
flame cycles off, then back ON thermostatically; when the flame cycles ON again,
automatic flame adjustment will resume. Automatic flame adjustment will also resume if
the operational mode is cycled out of, then back into THERMOSTAT mode or if the SET
temperature is changed.
THERMOSTAT OFF LCD Displays:
o MODE Zone: THERMO and OFF is displayed
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: LIGHT and light setting level is displayed
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator and current time is displayed
o AUX Zone: AUX and AUX setting is displayed
o FLAME Zone: Blank
THERMOSTAT ON LCD Displays:
o MODE Zone: THERMO and ON are displayed
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: LIGHT and light setting level is displayed
o FAN Zone: FAN and fan setting level is displayed
o TIME/PROG Zone: Current day indicator and current time is displayed
o AUX Zone: AUX and AUX setting is displayed
o FLAME Zone: A Flame Icon and flame setting level number is displayed
Thermostat Disable Feature
The Thermostat Mode (described above) may be disabled for applications where a
thermostat is not allowed or undesirable. When Thermostat Mode is Disabled:
o The Modes of operation will cycle between MANUAL ON and MANUAL OFF
(omitting THERMO).
o Program Operation (described below) is also disabled.
o The SET TEMP zone will be blank.